Skip to main content
ABB 3ADT218519S0121 — AC Drive (VFD) 480V

3ADT218519S0121 ABB DCS880-S01-0180-04 DC Converter, 400 VAC

MPN3ADT218519S0121
Active

ABB DCS880-S01-0180-04 DC converter, 2Q, 400 VAC, 0180 A, frame size H2, 3 analog inputs, 2 analog outputs, 55 dB(A), IP00 auxiliary terminals, active.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ADT218519S0121 — Input / Supply
ParameterValue
Frequency50 Hz
3ADT218519S0121 — Mechanical & Cooling
ParameterValue
Frame sizeH2
Degree of protection (IP)acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00
3ADT218519S0121 — Other specifications
ParameterValue
Sound55 dB(A)
Analog inputs3
Analog outputs2
Operating humidity (RHamβ)5...95%

Product details

The ABB 3ADT218519S0121 is a DCS880-S01-0180-04 DC converter — a 2-quadrant unit rated for 400 VAC input and 180 A output, built on the H2 frame size. It converts AC line power to a controlled DC output for motor armature or field supplies, regenerative loads, or DC bus regulation in industrial drives. It carries three analog inputs and two analog outputs for speed/torque reference, current feedback, or process signals — enough for a basic closed-loop DC drive without an extra I/O module.

The 180 A output is the continuous rating at the converter terminals — sized for a DC motor drawing that armature current under full load. The 400 VAC supply side matches a standard three-phase industrial mains at 50 Hz. The H2 frame defines the mechanical footprint and bus-bar layout; if you are replacing an existing H2-frame drive, the mounting holes and power connections line up. Auxiliary terminals are rated IP00 per IEC 60529 and IEC 60947-1 — no enclosure protection at the terminals themselves, so the converter must live inside a panel or cabinet that provides the required environmental seal. The 55 dB(A) noise level is typical for a forced-air-cooled drive of this power class; audible in a control room but unremarkable on a plant floor. Operating humidity range of 5 to 95% RH covers most indoor industrial environments without condensation protection. No special derating needed for high-humidity locations as long as the cabinet stays above dew point.

Frequently asked questions

What is the frame size of this converter?

The frame size is H2. That determines the physical mounting footprint and bus-bar arrangement.

What are the key ratings of this DC converter?

It is a 2-quadrant converter rated for 400 VAC input and 180 A continuous output. It has 3 analog inputs and 2 analog outputs. The auxiliary terminals are IP00, and the sound level is 55 dB(A).

How do I source this part?

This is an active-production item. Submit an RFQ for current lead time and pricing; we source it through the ABB channel.

MPN
3ADT218519S0121