ABB 3ADT218567S0261 — AC Drive (VFD) 480V

3ADT218567S0261 ABB DCS880-S02-5200-04R DC Converter, 5200 A

MPN3ADT218567S0261
Active

ABB DCS880-S02-5200-04R, DC converter, 4Q, 400 VAC, 5200 A, Frame Size H8, 82 dB(A), 3 analog inputs, 2 analog outputs.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ADT218567S0261 — Input / Supply
ParameterValue
Frequency50 Hz
3ADT218567S0261 — Mechanical & Cooling
ParameterValue
Frame sizeH8
Degree of protection (IP)acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00
3ADT218567S0261 — Other specifications
ParameterValue
Sound82 dB(A)
Analog inputs3
Analog outputs2
Operating humidity (RHamβ)5...95%

Product details

The ABB 3ADT218567S0261 is a DCS880-S02-5200-04R DC converter — a 4-quadrant regenerative unit rated for 5200 A at 400 VAC, 50 Hz. Frame size H8, so it's a large cabinet-grade drive; expect a substantial footprint and the need for a floor-standing enclosure, not a DIN-rail mount. The 82 dB(A) sound level means hearing protection is advisable within a few meters during full-load operation — plan for a separate drive room or acoustic enclosure if noise is a concern on the production floor.

I/O and control interface

The converter carries 3 analog inputs and 2 analog outputs — enough for basic speed reference, torque limit, and feedback loops without an external I/O expansion module. The auxiliary terminals are rated IP00 per IEC 60529, IEC 60947-1, and EN 60529, so those connections are live and unprotected; they must be housed inside the panel with proper finger-safe shrouding or a separate terminal enclosure.

Environmental tolerance

Operating humidity range is 5 to 95% RH (non-condensing), which covers most industrial environments from dry control rooms to humid mill floors. No derating curve is listed here, but for a 5200 A unit, forced-air or liquid cooling is typical — verify the installation manual for airflow clearance and ambient temperature limits before panel layout.

This is a current-production part, not a last-time-buy or obsolete line. No official successor or cross-reference exists — this is the current variant.

Frequently asked questions

What is the frame size of 3ADT218567S0261?

The listed frame size is H8. That is a large cabinet-grade frame — expect a floor-standing enclosure, not a DIN-rail mount.

What is the sound level of this DC converter?

The sound level is 82 dB(A). At that level, hearing protection is recommended within a few meters during full-load operation.

Where can I buy 3ADT218567S0261?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
3ADT218567S0261