Skip to main content
ABB 3ADT218587S0141 — AC Drive (VFD) 480V

3ADT218587S0141 ABB DCS880-S01-2000-04 DC Converter, 2000 A,

MPN3ADT218587S0141
Active

ABB DCS880-S01-2000-04 DC converter, 2Q, 400 VAC, 2000 A, frame size H6, 73 dB(A), 3 analog inputs, 2 analog outputs.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ADT218587S0141 — Input / Supply
ParameterValue
Frequency50 Hz
3ADT218587S0141 — Mechanical & Cooling
ParameterValue
Frame sizeH6
Degree of protection (IP)acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00
3ADT218587S0141 — Other specifications
ParameterValue
Sound73 dB(A)
Analog inputs3
Analog outputs2
Operating humidity (RHamβ)5...95%

Product details

The ABB 3ADT218587S0141 is a DCS880-S01-2000-04 DC converter — a 2-quadrant unit rated for 2000 A on a 400 VAC supply. It sits in frame size H6, which governs the mechanical footprint and bus-bar layout for the cabinet build.

The 2000 A rating is the continuous output at the stated line voltage — size your DC bus and fusing for that full current, not less. The 2Q topology means it handles motoring and regenerative braking in one direction only; if your application needs bidirectional torque or overhauling loads, you will need a 4Q variant. Frame H6 is a physical size class — expect a substantial cabinet footprint and bus-bar connections rated for the full current. The 73 dB(A) sound level is typical for a converter of this power class; plan for hearing protection if the drive is in a manned area. The analog complement — 3 inputs, 2 outputs — is enough for speed reference, torque limit, and a speed-feedback or load-signal output. No fieldbus interface is listed here, so plan on using the analog I/O or adding a communication option card if needed.

Environmental and installation notes

The converter is rated for 5 to 95 % relative humidity (non-condensing) and a 50 Hz supply. Auxiliary terminals carry an IP00 protection level per IEC 60529 and IEC 60947-1 — meaning they are not touch-safe; the cabinet door must interlock or require a tool to open.

Frequently asked questions

What is the frame size for this converter?

Frame size H6. That determines the mounting hole pattern, bus-bar spacing, and overall cabinet cutout required.

What is the sound level of this unit?

73 dB(A) at rated operation. Plan for acoustic enclosures or hearing protection if the drive is in a personnel area.

MPN
3ADT218587S0141