Skip to main content
ABB 3AUD0000003142 — AC Drive (VFD) 480V

ABB 3AUD0000003142 ACH580 HVAC Drive, 350 Hp, 414 A, 460 V

MPN3AUD0000003142
Active

ABB ACH580 HVAC packaged ultra-low harmonic drive with circuit breaker, UL: Pld 350 Hp, 414 A, 460 V, Frame R11, 3-phase, 440-480 V, IP21, NEMA Type 1, 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AUD0000003142 — Input / Supply
ParameterValue
Input voltage range440 ... 480 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000003142 — Power & Output
ParameterValue
Output current, light overload (UL rating)414 A
Output power, light overload (UL rating, Hp)350 Hp
3AUD0000003142 — Mechanical & Cooling
ParameterValue
Frame sizeR11
NEMA enclosure typeType1
Degree of protection (IP)IP21

Product details

The ABB 3AUD0000003142 is an ACH580-series HVAC packaged ultra-low harmonic drive with an integrated circuit breaker, rated for 350 Hp / 414 A under UL light-overload conditions at 460 V. That 414 A figure is the continuous output current the drive can sustain for variable-torque loads like fans and pumps — the dominant HVAC application — without derating. The integrated circuit breaker eliminates a separate panel component and reduces the single-point-of-failure count in the power path, which is exactly the kind of simplification a critical-facilities engineer wants when chasing concurrent maintainability.

Line-up and deployment context

Frame R11, 3-phase input 440–480 V, 50/60 Hz. The IP21 / NEMA Type 1 enclosure is clean indoor — suitable for a dedicated electrical room or mechanical penthouse where washdown isn't a concern. The ultra-low harmonic topology (active front end, not just a passive filter) keeps total harmonic distortion well below IEEE 519 thresholds, which matters when the drive shares a transformer with other VFDs or sensitive controls in the same rack. No separate line reactor or DC choke needed for harmonic compliance on most utility feeds.

Frequently asked questions

What is the frame size of 3AUD0000003142?

Frame size R11.

What is the input voltage and frequency for 3AUD0000003142?

440–480 V, 3-phase, 50/60 Hz.

Where can I buy 3AUD0000003142 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN