Skip to main content
ABB 3AUD0000003735 — AC Drive (VFD) 480V

3AUD0000003735 ACH580 HVAC Drive, 75 Hp, 96 A, 460 V

MPN3AUD0000003735
Active

ABB ACH580 HVAC enclosed ultra-low harmonic drive with circuit breaker, UL: Pld 75 Hp, 96 A, 460 V, R8 frame, IP21, NEMA 1, 3-phase, 440-480 V, 50/60 Hz. Active production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AUD0000003735 — Input / Supply
ParameterValue
Input voltage range440 ... 480 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000003735 — Power & Output
ParameterValue
Output current, light overload (UL rating)96 A
Output power, light overload (UL rating, Hp)75 Hp
3AUD0000003735 — Mechanical & Cooling
ParameterValue
Frame sizeR8
NEMA enclosure typeType1
Degree of protection (IP)IP21

Product details

The 3AUD0000003735 is an ABB ACH580 HVAC enclosed ultra-low harmonic drive with an integrated circuit breaker, delivering 75 Hp and 96 A at 460 V under UL light-overload conditions. Built on the R8 frame, it accepts 440-480 V three-phase input at 50/60 Hz and carries an IP21 rating with a NEMA Type 1 enclosure — suited for indoor HVAC mechanical-room installation where the drive sits in a controlled environment but still needs drip protection from condensation or sprinkler overspray. The integrated circuit breaker eliminates a separate disconnect in the line-up, saving two to three inches of panel width per drive. For a multi-drive chiller or air-handler bank, that adds up to meaningful enclosure space recovery.

Frequently asked questions

What are the key output ratings for 3AUD0000003735?

Under UL light-overload duty it delivers 75 Hp and 96 A at 460 V. The drive is an enclosed ultra-low harmonic HVAC unit with an integrated circuit breaker.

What frame size and enclosure does this drive use?

It is an R8 frame with IP21 protection and a NEMA Type 1 enclosure. That means it is drip-proof and intended for indoor installation — not rated for washdown or outdoor exposure.

What input voltage and frequency does 3AUD0000003735 accept?

It accepts 440-480 V three-phase at 50/60 Hz — standard North American 460 V nominal with tolerance for 440 V grids.

Where can I buy 3AUD0000003735 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figure or price is published here.

MPN
3AUD0000003735