ABB 3AXD50000031886 — AC Drive (VFD) 480V

ABB 3AXD50000031886 Drive Control Unit, 0.55 kW, 1.8 A, MODB

MPN3AXD50000031886
Active

ABB drive control unit, frame size R0, 0.55 kW normal-use output at 1.8 A, 380–480 V three-phase input, MODBUS, IP20, active production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000031886 — Power & Output
ParameterValue
Output power, normal duty0.55 kW
Output current, normal duty1.8 A
Output power, heavy duty0.37 kW
Output current, heavy duty1.2 A
Output power, light overload0.55 kW
Output current, light overload1.7 A
Output current, light overload (UL rating)1.6 A
Apparent power output1.2 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)0.75 Hp
Standby power loss10 W
3AXD50000031886 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000031886 — Mechanical & Cooling
ParameterValue
Frame sizeR0
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000031886 — Environmental
ParameterValue
Temperature rating (max.)Maximum 50 °C
3AXD50000031886 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)0.5 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)1.1 A

Product details

Output ratings and duty cycles

The 3AXD50000031886: Normal-use output (Pn) is 0.55 kW at 1.8 A; heavy-duty (PhD) is 0.37 kW at 1.2 A. Light-overload use (PlD) matches normal use at 0.55 kW but with a slightly lower current of 1.7 A. Under UL listing, normal-use output is 1.6 A, heavy-duty is 1.1 A at 0.5 Hp, and light-overload is 0.75 Hp. The IE2 efficiency level and 0.98 power factor keep standby losses at 10 W and total power consumption at 28 W.

The unit provides 5 digital inputs and 2 digital outputs, plus 2 analog inputs and 1 analog output. MODBUS is the sole hardware communication interface — no industrial Ethernet port is fitted. Ambient temperature limit is 50 °C, humidity range 5–95% non-condensing, and altitude rating 1000 m. IP20 enclosure, NEMA Open Type, suitable for cabinet mounting.

Frequently asked questions

What is the SCIP number for this drive control unit?

The SCIP number is e1a24d5c-f26a-456d-a398-fbda49d35a05, registered in Finland.

What are the key output ratings?

Normal-use output is 0.55 kW at 1.8 A; heavy-duty is 0.37 kW at 1.2 A. Under UL, normal-use output is 1.6 A, heavy-duty 1.1 A at 0.5 Hp.

MPN