Skip to main content
ABB 3AXD50000034602 — AC Drive (VFD) 480V

ABB 3AXD50000034602 ACQ580-01 Drive, 55 kW, 106 A

MPN3AXD50000034602
Active

ABB, ACQ580-01 series, LV AC wall-mounted drive, 3AXD50000034602, 55 kW / 106 A normal use, 380–480 V, IP21, frame R5.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000034602 — Power & Output
ParameterValue
Output power, normal duty55 kW
Output current, normal duty106 A
Output power, heavy duty45 kW
Output current, heavy duty87 A
Output power, light overload55 kW
Output current, light overload100 A
Apparent power output73 kV·A
Efficiency class (IE)IE2
Standby power loss24 W
3AXD50000034602 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000034602 — Mechanical & Cooling
ParameterValue
Frame sizeR5
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted
3AXD50000034602 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50000034602 is an LV AC wall-mounted drive rated for 55 kW normal-use output at 106 A, with a 380–480 V three-phase input. It's built for water and wastewater applications, frame size R5, IP21, NEMA Type 1 enclosure.

Duty ratings and real-world headroom

Normal-use (Pn) sits at 55 kW / 106 A; heavy-duty (PhD) drops to 45 kW / 87 A. Light-overload (PlD) matches normal use at 55 kW but current is 100 A — so the drive is current-limited in light-overload, not power-limited. That 6 A gap between normal and light-overload current tells you the drive's thermal model expects a different duty cycle curve for water/wastewater pumping profiles.

Wall-mounted, IP21, NEMA Type 1 — suitable for indoor clean environments. Ambient max 40 °C, altitude up to 4000 m derated. Operating humidity 5–95% RH non-condensing. Standby loss 24 W, sound pressure 63 dB(A). Power factor 0.98, apparent power 73 kVA. Includes control unit; 2 analog inputs, 2 analog outputs, 6 digital inputs / 3 digital outputs. Communication via CAN bus; no onboard Industrial Ethernet.

Frequently asked questions

What are the normal-use and heavy-duty output ratings?

Normal use: 55 kW / 106 A. Heavy-duty use: 45 kW / 87 A.

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863; REACH declaration confirms substances above 0.1 mass percentage (date 20250905). SCIP number 24d7f559-8ddc-4469-93c7-ad912823d754 Finland.

What is the enclosure rating and mounting?

IP21, NEMA Type 1, wall-mounted. Suitable for indoor use with ambient up to 40 °C and altitude up to 4000 m.

MPN