Skip to main content
ABB 3AXD50000035902 — AC Drive (VFD) 480V

3AXD50000035902 ACS880-01-019A-4 11 kW Drive, IP21

MPN3AXD50000035902
Active

ABB ACS880-01-019A-4, LV AC industrial wall-mounted single drive, 11 kW / 19 A normal duty, 7.5 kW / 13 A heavy duty, frame size R2, IP21.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000035902 — Power & Output
ParameterValue
Output power, normal duty11 kW
Output current, normal duty19 A
Output power, heavy duty7.5 kW
Output current, heavy duty13 A
Output power, light overload11 kW
Output current, light overload19 A
Output current, light overload (UL rating)19 A
Apparent power output14 kV·A
Efficiency class (IE)IE2
Standby power loss24 W
3AXD50000035902 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000035902 — Mechanical & Cooling
ParameterValue
Frame sizeR2
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted
3AXD50000035902 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50000035902 is the order code for an ACS880-01-019A-4 drive, a wall-mounted LV AC single drive rated for 11 kW normal-duty output at 19 A from a 380–480 V three-phase supply. Heavy-duty rating drops to 7.5 kW / 13 A for constant-torque loads. Frame size R2, IP21 enclosure, maximum ambient 40 °C.

Duty ratings and load profile

Normal-use output current is 19 A at 11 kW; light-overload use holds the same 19 A at 11 kW. Heavy-duty use derates to 13 A at 7.5 kW. Efficiency class is IE2. Standby loss runs 24 W; power consumption at rated load is 289 W. Apparent power output is 14 kV·A.

Operating humidity range 5–95 % RH, altitude rating 4000 m, sound pressure level 59 dB(A). NEMA Type 1 equivalent. Wall-mounted. Two analog inputs, two analog outputs, six digital inputs, two digital outputs. CAN protocol on board; no industrial Ethernet interface.

Frequently asked questions

What are the normal-duty and heavy-duty ratings?

Normal-duty output is 11 kW at 19 A; heavy-duty output is 7.5 kW at 13 A. Light-overload use matches normal-duty at 11 kW / 19 A.

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (declaration date 20240508). REACH compliant with substance declaration above 0.1% (date 20250320).

What is the enclosure rating and mounting style?

IP21, NEMA Type 1. Wall-mounted. Frame size R2.

What communication protocols are supported?

CAN protocol is on board. No industrial Ethernet interface (0 hardware interfaces for Industrial Ethernet).

MPN