Skip to main content
ABB 3AXD50000036403 — AC Drive (VFD) 480V

ABB 3AXD50000036403 ACS880 Drive Module, 2.2 kW, 6 A

MPN3AXD50000036403
Active

ABB ACS880-M04-06A0-5 LV AC machinery drive module, IEC: Pn 2.2 kW, 6 A, 400 V, UL: Pld 3 Hp, 5.5 A, 480 V, frame size R1, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000036403 — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty6 A
Output power, heavy duty2.2 kW
Output current, heavy duty5 A
Output power, light overload2.2 kW
Output current, light overload5.5 A
Output current, light overload (UL rating)5.5 A
Apparent power output4.2 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)3 Hp
Standby power loss30 W
3AXD50000036403 — Input / Supply
ParameterValue
Input voltage range380 ... 500 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000036403 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000036403 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000036403 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)3 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)5 A

Product details

The ABB 3AXD50000036403 is an ACS880-M04-06A0-5 LV AC machinery drive module, built for 3-phase 380–500 V supplies. It delivers 2.2 kW at 6 A under normal use (light overload at 5.5 A, heavy-duty at 5 A). The R1 frame keeps it compact for panel mounting, and the IP20 enclosure suits clean indoor environments. Communication is over CAN, with 2 analog inputs and 2 analog outputs for feedback or control signals.

Ratings across duty classes

The module carries three output ratings: normal use (Pn) 2.2 kW at 6 A, light-overload (PlD) 2.2 kW at 5.5 A, and heavy-duty (PhD) 2.2 kW at 5 A. Under UL listing, light-overload is 3 Hp at 5.5 A, heavy-duty 3 Hp at 5 A. The 0.98 power factor and IE2 efficiency level keep losses low; standby loss is 30 W. Sound level is 47 dB(A) — noticeable in a quiet control room but fine in a machine bay.

Integration notes

The module includes a PC connection for commissioning. It mounts as a module (not a standalone drive) and includes a lithium coin cell CR2032 (2 pcs, 220 mAh, 3 V) for backup — account for battery replacement in your maintenance schedule. The 6 digital inputs and 5 digital outputs give enough I/O for basic machine control without an extra I/O block. No industrial Ethernet interface is onboard; CAN is the only fieldbus, so plan your network gateway accordingly.

Frequently asked questions

What are the key output ratings for this drive module?

Normal use: 2.2 kW at 6 A. Light-overload: 2.2 kW at 5.5 A. Heavy-duty: 2.2 kW at 5 A. UL ratings: 3 Hp at 5.5 A (light-overload) and 3 Hp at 5 A (heavy-duty).

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU (date 20240508) and REACH compliant (date 20250905). The SCIP number is 818a5b81-6568-489f-a9a8-e87d3682c8f8 Finland.

What is the input voltage and frequency range?

380–500 V, 3-phase, 47.5–63 Hz.

What is the frame size and protection rating?

Frame size R1, IP20.

MPN
3AXD50000036403