Duty ratings and headroom
The 3AXD50000038939: Normal-use output is 1.5 kW at 4 A; heavy-duty use derates to 1.1 kW at 3.3 A. Light-overload use holds at 1.5 kW but current drops to 3.8 A. The drive carries an IE2 efficiency level and consumes 60 W from the supply at rated load.
Frame size R1, wall-mounted, IP21 enclosure with NEMA Type 1 rating. Ambient temperature limited to 40 °C; altitude rated to 1000 m. Operating humidity range 5–95 % RH. Standby loss is 14 W.