Skip to main content
ABB 3AXD50000038940 — AC Drive (VFD) 480V

ABB 3AXD50000038940 ACS580-01-05A7-4 VFD, 2.2 kW, 5.6 A

MPN3AXD50000038940
Active

ABB ACS580-01-05A7-4 general-purpose wall-mounted VFD, 2.2 kW / 5.6 A at 400 V, IP21, Type 1, frame R1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000038940 — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, heavy duty1.5 kW
Output current, heavy duty4.0 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Apparent power output3.9 kV·A
Efficiency class (IE)IE2
Standby power loss14 W
3AXD50000038940 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000038940 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted
3AXD50000038940 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The 3AXD50000038940 is the order code for an ABB ACS580-01-05A7-4, a low-voltage AC general-purpose wall-mounted drive. It's rated for 2.2 kW normal-use output at 5.6 A on a 380...480 V three-phase supply, 47.5...63 Hz input. Frame size R1, IP21, NEMA Type 1 enclosure. Ambient temperature max 40 °C, altitude 1000 m without derating. Heavy-duty use knocks output down to 1.5 kW / 4.0 A; light-overload stays at 2.2 kW / 5.3 A. That's the IEC duty cycle — normal use for constant torque, heavy-duty for demanding loads like conveyors or pumps with high starting torque.

Built-in I/O includes 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is CAN-based; no onboard industrial Ethernet. The standby loss is 14 W, power consumption 85 W at rated load. Efficiency class IE2. Wall-mounted, so plan for gland plate clearance and side ventilation. Sound level is 59 dB(A) — noticeable in a quiet control room but fine on a plant floor.

Frequently asked questions

What compliance documentation does this drive have?

RoHS compliant per EU 2011/65/EU and amendment 2015/863 (declaration date 20240508). REACH compliant with substances above 0.1 mass percentage (declaration date 20250905). SCIP number a5c3dd71-8ecd-44d9-98e4-45c53b6836e1 Finland is on file.

What is the altitude rating for this drive?

Rated for 1000 m altitude without derating. Above that, standard ABB derating curves apply.

MPN
3AXD50000038940