ABB 3AXD50000038987 — AC Drive (VFD) 480V

ABB 3AXD50000038987 ACH580-01 HVAC Drive, 5.5 kW, 12.6 A

MPN3AXD50000038987
Active

ABB ACH580-01 series, LV AC wall-mounted HVAC drive, 3AXD50000038987, 5.5 kW / 12.6 A normal use, 380-480 V, IP21, BACnet.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000038987 — Power & Output
ParameterValue
Output power, normal duty5.5 kW
Output current, normal duty12.6 A
Output power, heavy duty4.0 kW
Output current, heavy duty9.4 A
Output power, light overload5.5 kW
Output current, light overload12.0 A
Output current, light overload (UL rating)11.0 A
Apparent power output8.7 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)7.5 Hp
Standby power loss14 W
3AXD50000038987 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000038987 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted
3AXD50000038987 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000038987 — Electrical
ParameterValue
Technical UL/Output Current, Heavy-Duty Use (UL)7.6 A

Product details

Drive identity and headline ratings

The ABB 3AXD50000038987 is an ACH580-01-12A7-4 LV AC wall-mounted drive for HVAC applications, rated 5.5 kW normal-use output at 12.6 A (IEC) and 7.5 Hp light-overload (UL) at 11.0 A. Input voltage is 380-480 V three-phase, 47.5-63 Hz.

Normal-use output (Pn) is 5.5 kW at 12.6 A — that's the continuous rating for typical fan and pump loads. Light-overload (PlD) matches normal use at 5.5 kW but current is capped at 12.0 A, so the drive can handle short-duration overloads without tripping. The UL column shows 7.6 A heavy-duty and 11.0 A light-overload — important for North American installations where UL 508C listing governs the branch-circuit protection.

Enclosure, protection, and mounting

IP21 degree of protection with NEMA Type 1 enclosure — suitable for indoor, clean environments where dripping water and small tools are the main concern. Ambient temperature limited to 40 °C maximum; operating humidity up to 95% RH (non-condensing). Altitude rating of 1000 m without derating.

Built-in BACnet communication protocol — no option card needed for building automation integration. Two analog inputs, two analog outputs, six digital inputs, three digital outputs. No industrial Ethernet interface on this variant, so BACnet MS/TP (RS-485) is the primary fieldbus. Standby loss is 14 W; power consumption at rated load is 213 W.

Frequently asked questions

What are the key ratings for this drive?

Normal-use output is 5.5 kW at 12.6 A (IEC). Heavy-duty output is 4.0 kW at 9.4 A. UL light-overload is 7.5 Hp at 11.0 A. Input voltage is 380-480 V three-phase.

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU (date 20240508). REACH declaration (date 20250905) confirms substances > 0.1 mass percentage. SCIP number a5c3dd71-8ecd-44d9-98e4-45c53b6836e1 (Finland). UL and IEC ratings are listed on the nameplate.

MPN
3AXD50000038987