ABB 3AXD50000039012 — AC Drive (VFD) 480V

ABB 3AXD50000039012 ACH580-01 HVAC Drive, 15 kW, 32 A, IP55

MPN3AXD50000039012
Active

ABB ACH580-01 wall-mounted HVAC drive, 3AXD50000039012, 15 kW / 32 A normal use, 380–480 V, IP55, NEMA 12, BACnet, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000039012 — Power & Output
ParameterValue
Output power, normal duty15 kW
Output current, normal duty32 A
Output power, heavy duty11.0 kW
Output current, heavy duty24.6 A
Output power, light overload15.0 kW
Output current, light overload30.4 A
Output current, light overload (UL rating)27.0 A
Apparent power output22 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)20 Hp
Standby power loss16 W
3AXD50000039012 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000039012 — Mechanical & Cooling
ParameterValue
Frame sizeR3
NEMA enclosure typeType12
Degree of protection (IP)IP55
Mounting typeWall-mounted
3AXD50000039012 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000039012 — Electrical
ParameterValue
Technical UL/Output Current, Heavy-Duty Use (UL)21.0 A

Product details

The ABB 3AXD50000039012 is an ACH580-01 wall-mounted drive for HVAC applications, rated 15 kW normal use at 32 A on a 380–480 V three-phase supply. Heavy-duty use delivers 11.0 kW at 24.6 A; light-overload use reaches 15.0 kW at 30.4 A. The IP55 enclosure with NEMA Type 12 rating suits indoor installations where dust and dripping water are present. BACnet communication is built in, with 2 analog inputs and 2 analog outputs for BMS integration. Standby loss is 16 W, and the drive carries IE2 efficiency.

Frame size R3, wall-mounted. Ambient temperature limited to 40 °C maximum. Operating humidity up to 95%. The enclosure is IP55 / NEMA 12, so gland plates and conduit entries must maintain the seal. Digital I/O: 6 inputs, 3 outputs. No industrial Ethernet interface; BACnet is the fieldbus. The control unit is included. A lithium coin cell (CR2032, 220 mAh) backs the real-time clock.

UL ratings

Under UL listing, heavy-duty use is rated 21.0 A; light-overload use is 20 Hp at 27.0 A. These differ from the IEC ratings (24.6 A heavy-duty, 30.4 A light-overload) and should be used for North American installations.

Frequently asked questions

What compliance documentation is available for this drive?

RoHS compliance dated 20240508 per EU Directive 2011/65/EU, REACH compliance dated 20250905 (contains substances > 0.1 mass percentage), and SCIP number 7ab39eb4-9330-424a-b7ff-fcf491eb4b83 Finland.

What are the key ratings for this drive?

Normal use: 15 kW, 32 A. Heavy-duty use: 11.0 kW, 24.6 A. Light-overload use: 15.0 kW, 30.4 A. Input: 380–480 V, 3-phase, 47.5–63 Hz. Enclosure: IP55 / NEMA 12. Efficiency: IE2.

MPN
3AXD50000039012