Skip to main content
ABB 3AXD50000039018 — AC Drive (VFD) 480V

ABB 3AXD50000039018 ACQ580-01 Drive, 2.2 kW, 5.6 A, IP21

MPN3AXD50000039018
Active

ABB ACQ580-01 series, LV AC wall-mounted drive, 3AXD50000039018, 2.2 kW / 5.6 A normal use, 380-480 V 3-phase, IP21, frame R1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000039018 — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, heavy duty1.5 kW
Output current, heavy duty4.0 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Apparent power output3.9 kV·A
Efficiency class (IE)IE2
Standby power loss14 W
3AXD50000039018 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000039018 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted
3AXD50000039018 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

Drive identity and duty ratings

It delivers 2.2 kW output power at 5.6 A under normal use, with a heavy-duty rating of 1.5 kW at 4.0 A. Input is 380-480 V three-phase, 47.5-63 Hz, and the drive carries an IE2 efficiency level. Frame size R1, wall-mounted, IP21 with NEMA Type 1 enclosure. That means it's splash-resistant and suited for indoor installation away from washdown spray. Ambient max is 40 °C, and it'll operate up to 4000 m altitude without derating concerns for most installations.

The drive carries 2 analog inputs, 2 analog outputs, and 6 digital inputs with 3 digital outputs. That's enough for a basic pressure transducer, a setpoint, and a run/fault handshake to a PLC. Communication is via CAN bus — no onboard Ethernet, so if you need Modbus TCP or PROFINET, you'll be adding an option module. Standby loss sits at 14 W, and total power consumption at rated load is 85 W. The control unit is included. The internal lithium coin cell (CR2032, 220 mAh) keeps the real-time clock and parameter backup alive during power-down. Sound level is 59 dB(A) — quiet enough for a pump room but not silent.

Frequently asked questions

What is the SCIP number for this drive?

SCIP number a5c3dd71-8ecd-44d9-98e4-45c53b6836e1, registered in Finland under WEEE Category 5.

What compliance documentation does ABB provide for this drive?

RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 (dated 20240508). REACH declaration confirms substances > 0.1% mass percentage (dated 20250905).

What are the normal-use and heavy-duty output ratings?

Normal use (light overload): 2.2 kW at 5.6 A. Heavy duty: 1.5 kW at 4.0 A. Light-overload current is 5.3 A.

MPN
3AXD50000039018