ABB 3AXD50000039031 — AC Drive (VFD) 480V

ABB 3AXD50000039031 ACQ580-01 VFD, 22 kW, 45 A, IP21

MPN3AXD50000039031
Active

ABB ACQ580-01 wall-mounted drive, 3AXD50000039031, 22 kW normal use, 45.0 A, 380-480 V, IP21, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000039031 — Power & Output
ParameterValue
Output power, normal duty22 kW
Output current, normal duty45.0 A
Output power, heavy duty18.5 kW
Output current, heavy duty37.7 A
Output power, light overload22 kW
Output current, light overload42.8 A
Apparent power output31 kV·A
Efficiency class (IE)IE2
Standby power loss16 W
3AXD50000039031 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000039031 — Mechanical & Cooling
ParameterValue
Frame sizeR3
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted
3AXD50000039031 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50000039031 is an ACQ580-01 wall-mounted drive rated for 22 kW normal use (45.0 A) and 18.5 kW heavy-duty use (37.7 A) on a 380-480 V three-phase supply. Frame size R3, IP21 enclosure, IE2 efficiency class. It's built for water and wastewater applications — the description calls it out directly.

Heavy-duty use at 37.7 A covers constant-torque loads like screw feeders or positive-displacement pumps. Ambient temperature range -15 to 50 °C, but derate above 40 °C — the 40 °C figure is the maximum for full output.

Wall-mounted unit, IP21, NEMA Type 1. Rated for installation up to 4000 m altitude — above 1000 m, derate current per IEC guidelines. Operating humidity 5-95% non-condensing. Standby loss 16 W; sound level 76 dB(A) at full load. Includes the control unit; CAN communication is onboard — no industrial Ethernet interface on this variant.

Frequently asked questions

What is the SCIP number for this drive?

SCIP number 8e1cd225-4cd2-4db1-8a7b-419a51ce1ae3 Finland is registered for this part.

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863, REACH registered (contains substances > 0.1 mass percentage). SCIP number on file.

MPN
3AXD50000039031