Skip to main content
ABB 3AXD50000039045 — AC Drive (VFD) 480V

ABB 3AXD50000039045 ACQ580-01 Drive, 11 kW, 25 A, IP55

MPN3AXD50000039045
Active

ABB ACQ580-01 wall-mounted drive, 3AXD50000039045, 11 kW, 25.0 A, 380-480 V, IP55, frame R2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000039045 — Power & Output
ParameterValue
Output power, normal duty11 kW
Output current, normal duty25.0 A
Output power, heavy duty7.5 kW
Output current, heavy duty17.0 A
Output power, light overload11 kW
Output current, light overload23.8 A
Apparent power output17 kV·A
Efficiency class (IE)IE2
Standby power loss15 W
3AXD50000039045 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000039045 — Mechanical & Cooling
ParameterValue
Frame sizeR2
NEMA enclosure typeType12
Degree of protection (IP)IP55
Mounting typeWall-mounted
3AXD50000039045 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The 3AXD50000039045: Input is 380 to 480 V three-phase, 47.5 to 63 Hz. The drive is IP55 / NEMA Type 12, so it handles hose-down and dust common in treatment plants and lift stations. Ambient limit is 40 °C; altitude rating goes to 4000 m — useful if the installation is at elevation.

Onboard I/O: 6 digital inputs, 3 digital outputs, 2 analog inputs, 2 analog outputs. Communication is CAN — no onboard Ethernet, so if the site uses PROFINET or EtherNet/IP, plan for an optional fieldbus adapter. The control unit is included in the delivery.

Sourcing note

Frame R2, wall-mounted. Standby loss is 15 W; efficiency class IE2. If you are filling a BOM line for a water/wastewater skid or a pump retrofit, this is the drive to specify.

Frequently asked questions

What is the SCIP number for this drive?

The SCIP number is f016e531-e6de-4d1f-aec7-2a367861600c Finland.

What compliance documentation is available?

RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508), and REACH declaration (date 20250905) confirming substances above 0.1 mass percentage.

What are the key output ratings?

Normal use: 11 kW, 25.0 A. Heavy-duty use: 7.5 kW, 17.0 A. Light-overload use: 11 kW, 23.8 A.

MPN
3AXD50000039045