The 3AXD50000039045: Input is 380 to 480 V three-phase, 47.5 to 63 Hz. The drive is IP55 / NEMA Type 12, so it handles hose-down and dust common in treatment plants and lift stations. Ambient limit is 40 °C; altitude rating goes to 4000 m — useful if the installation is at elevation.
Onboard I/O: 6 digital inputs, 3 digital outputs, 2 analog inputs, 2 analog outputs. Communication is CAN — no onboard Ethernet, so if the site uses PROFINET or EtherNet/IP, plan for an optional fieldbus adapter. The control unit is included in the delivery.
Sourcing note