3AXD50000041429 — Power & Output
ParameterValue
Output power, normal duty315 kW
Output current, normal duty585 A
Output power, heavy duty250 kW
Output current, heavy duty429 A
Output power, light overload315 kW
Output current, light overload575 A
Output current, light overload (UL rating)573 A
Apparent power output405 kV·A
Output power, light overload (UL rating, Hp)450 Hp
3AXD50000041429 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000041429 — Mechanical & Cooling
ParameterValue
Frame sizeR10
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeCabinet-built
3AXD50000041429 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000041429 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)350 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)414 A

Product details

Enclosure, mounting, and environment

The 3AXD50000041429: This is a cabinet-built drive, frame size R10, with IP21 protection and NEMA Type 1 enclosure. Ambient temperature maximum is 40 °C; operating humidity range is 5 to 95% non-condensing. The drive includes a control unit and is supplied with a lithium coin cell (CR2032, 220 mAh, 3 V) for backup.

Communications and I/O

The drive communicates via CAN protocol. It has 2 analog inputs, 2 analog outputs, and 6 digital inputs / 3 digital outputs. No industrial Ethernet interface is included on this base configuration.

Sourcing note

This is a current-production, active-line item. For lead time and pricing, submit an RFQ against the 3AXD50000041429 order code. The drive is specified into a BOM as a cabinet-built unit; confirm panel layout and gland-plate dimensions with the R10 frame drawing before committing the line.

Frequently asked questions

What are the normal-use and heavy-duty output ratings?

Normal-use (light-overload) output is 315 kW / 585 A (IEC) or 450 Hp / 573 A (UL). Heavy-duty output is 250 kW / 429 A (IEC) or 350 Hp / 414 A (UL).

What compliance documentation is available for this drive?

RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508). REACH declaration (date 20250905) confirms substances above 0.1 mass percentage. SCIP number e531a9e8-f7f6-4242-8b63-c885daa80d86 Finland. UL ratings are provided for heavy-duty and light-overload use.

What is the SCIP number for this drive?

The SCIP number is e531a9e8-f7f6-4242-8b63-c885daa80d86 Finland.

Does the drive include a control unit?

Yes, the listing includes a control unit.