ABB 3AXD50000041430 — AC Drive (VFD) 480V

ABB 3AXD50000041430 ACS580-07 Cabinet Drive, 355 kW, 650 A

MPN3AXD50000041430
Active

ABB ACS580-07 cabinet-built drive, 3AXD50000041430, 355 kW / 650 A normal duty, 250 kW / 477 A heavy duty, 380–480 V, IP21, Type 1, includes control unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000041430 — Power & Output
ParameterValue
Output power, normal duty355 kW
Output current, normal duty650 A
Output power, heavy duty250 kW
Output current, heavy duty477 A
Output power, light overload355 kW
Output current, light overload634 A
Output current, light overload (UL rating)623 A
Apparent power output450 kV·A
Output power, light overload (UL rating, Hp)500 Hp
3AXD50000041430 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000041430 — Mechanical & Cooling
ParameterValue
Frame sizeR10
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeCabinet-built
3AXD50000041430 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000041430 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)400 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)477 A

Product details

The 3AXD50000041430: Three duty ratings let you match the drive to the load profile. Normal use (Pn 355 kW, In 650 A) covers constant-torque applications like conveyors and pumps. Heavy-duty use (PhD 250 kW, IhD 477 A) handles higher overloads — crushers, centrifuges, mixers. Light-overload use (PlD 355 kW, IlD 634 A) suits variable-torque loads like fans and centrifugal pumps where peak current is brief. The UL listing mirrors these: 400 Hp heavy-duty, 500 Hp light-overload.

The drive provides 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is via CAN bus; there are no onboard industrial Ethernet interfaces. Plan for a separate gateway or fieldbus adapter if Ethernet is required.

Rated for ambient temperatures up to 40 °C and operating humidity 5–95% non-condensing. Acoustic noise is 72 dB(A). The cabinet-built design (frame R10) includes a lithium coin cell (CR2032, 220 mAh) for backup. Power consumption at rated load is 11200 W; apparent power output is 450 kV·A.

Frequently asked questions

What are the key output ratings for this drive?

Normal use: 355 kW / 650 A. Heavy-duty use: 250 kW / 477 A. Light-overload use: 355 kW / 634 A. UL equivalents: 400 Hp heavy-duty, 500 Hp light-overload.

What compliance documentation is available?

RoHS compliant per EU 2011/65/EU and 2015/863 (date 20240508). REACH declaration (date 20250905). SCIP: e531a9e8-f7f6-4242-8b63-c885daa80d86 Finland. Ecodesign exempt per EU 2019/1781 §2.3.e.

What is the enclosure and protection rating?

IP21 and NEMA Type 1. Cabinet-built, frame size R10.

Does this drive include a control unit?

Yes, the listing includes the control unit.

MPN