Skip to main content
ABB 3AXD50000041433 — AC Drive (VFD) 480V

ABB 3AXD50000041433 Cabinet-Built Drive, 500 kW, 880 A

MPN3AXD50000041433
Active

ABB ACS580-07 cabinet-built drive, IEC: Pn 500 kW, 880 A, 400 V, UL: Pld 700 Hp, 807 A, 480 V (3AXD50000041433).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000041433 — Power & Output
ParameterValue
Output power, normal duty500 kW
Output current, normal duty880 A
Output power, heavy duty400 kW
Output current, heavy duty725 A
Output power, light overload500 kW
Output current, light overload865 A
Output current, light overload (UL rating)807 A
Apparent power output610 kV·A
Output power, light overload (UL rating, Hp)700 Hp
3AXD50000041433 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000041433 — Mechanical & Cooling
ParameterValue
Frame sizeR11
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeCabinet-built
3AXD50000041433 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000041433 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)500 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)625 A

Product details

The 3AXD50000041433: Normal-use output (Pn) is 500 kW at 880 A; light-overload use (PlD) also rates 500 kW but at 865 A. Heavy-duty use (PhD) drops to 400 kW at 725 A. Under UL listing, light-overload output is 700 Hp at 807 A, and heavy-duty UL output is 500 Hp at 625 A. Apparent power output is 610 kV·A.

Input and Environment

Input voltage range is 380 to 480 V at 47.5 to 63 Hz, three-phase. Maximum ambient temperature is 40 °C, with operating humidity 5 to 95%. Sound pressure level is 71 dB(A). The drive is cabinet-built, so it is excluded from EU ecodesign energy efficiency reporting per Regulation EU/2019/1781 §2.3.e.

The drive provides 2 analog inputs and 2 analog outputs, plus 6 digital inputs and 3 digital outputs. Communication is via CAN protocol; no onboard Industrial Ethernet interface.

Frequently asked questions

What are the key output ratings?

Normal-use output is 500 kW at 880 A; heavy-duty use is 400 kW at 725 A. Under UL, light-overload is 700 Hp at 807 A.

What does the drive include?

It includes the control unit.

What is the enclosure rating?

IP21 with NEMA Type 1 enclosure.

MPN