Skip to main content
ABB 3AXD50000047394 — AC Drive (VFD) 480V

ABB 3AXD50000047394 ACS880-11 Regenerative Drive, 75 kW, 145

MPN3AXD50000047394
Active

ABB ACS880-11, LV AC industrial wall-mounted regenerative single drive, IEC: Pn 75 kW, 145 A, 400 V (3AXD50000047394).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000047394 — Power & Output
ParameterValue
Output power, normal duty75 kW
Output current, normal duty145 A
Output power, heavy duty55 kW
Output current, heavy duty105 A
Output power, light overload75 kW
Output current, light overload138 A
Apparent power output100 kV·A
Efficiency class (IE)IE2
Standby power loss75 W
3AXD50000047394 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000047394 — Mechanical & Cooling
ParameterValue
Frame sizeR8
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted
3AXD50000047394 — Environmental
ParameterValue
Temperature rating (max.)Maximum +55 °C

Product details

The ABB 3AXD50000047394 is a wall-mounted, low-voltage AC industrial single drive rated for 75 kW normal-duty output (Pn) at 145 A continuous current (In) on a 380–415 V three-phase supply. It handles heavy-duty use at 55 kW / 105 A (PhD / IhD) and light-overload use at 75 kW / 138 A (PlD / IlD). The R8 frame size and IP21 enclosure (NEMA Type 1) suit panel-mount or standalone wall installations where regenerative braking energy is fed back to the line.

The 105 A heavy-duty (IhD) rating covers high-starting-torque or cyclic loads like crushers or conveyors; the 138 A light-overload (IlD) rating suits variable-torque applications like fans and pumps where overloads are brief. Apparent power output is 100 kV·A, giving headroom for transformer-coupled or multi-motor groups. Standby loss sits at 75 W — figure that into panel cooling calculations for the R8 frame.

Environmental limits and mounting

Rated for maximum +55 °C ambient, 5–95% RH (non-condensing), and altitude up to 4000 m. The IP21 / NEMA Type 1 enclosure means it's drip-proof but not dust-tight; mount indoors or in a filtered cabinet. Sound level is 68 dB(A).

I/O, communication, and auxiliary details

Includes the control unit with 2 analog inputs, 2 analog outputs, 6 digital inputs, and 2 digital outputs. Communication is via CAN (no onboard Industrial Ethernet). The drive contains two CR2032 lithium coin cells (220 mAh, 3 V each) for real-time clock backup. Power consumption at rated load is 2621 W; power factor is unity (1.0). Frequency range is 47.5–63 Hz.

Frequently asked questions

What is the SCIP number for this drive?

The SCIP number is fbdafeba-e24d-4944-bd9b-d49273a010e5 Finland.

What are the output current ratings for normal, heavy-duty, and light-overload use?

Normal-duty (In) is 145 A, heavy-duty (IhD) is 105 A, and light-overload (IlD) is 138 A.

What is the maximum ambient temperature and altitude rating?

Maximum ambient temperature is +55 °C and maximum altitude is 4000 m.

MPN
3AXD50000047394