The 3AXD50000047491: This drive carries three distinct output ratings. Heavy-duty (PhD) drops to 3.0 kW / 8.0 A, which applies for constant-torque applications such as conveyors or positive-displacement compressors where you need sustained torque at low speed. Light-overload (PlD) sits at 4.0 kW / 9.5 A, a middle ground for applications with occasional peak demand. Pick the duty class that matches your load profile; the drive's thermal design and IGBT sizing are optimized for the cycle you select.
Wall-mounted in an IP21 / NEMA Type 1 enclosure, frame size R3. Ambient temperature maxes at +55 °C, altitude to 4000 m without derating.