This ABB 3AXD50000047766 is a live-production general-purpose drive module — frame R1, 1.1 kW normal-duty output at 3.3 A on a 380–480 V three-phase supply. The unit ships as a control unit included, so it's ready to wire into a panel without sourcing a separate control head. IP20, open-type NEMA, mounts as a module on a backplate or DIN rail adaptor.
The drive carries three duty curves. Normal use (Pn) is 1.1 kW at 3.3 A — that's the continuous rating for a standard variable-torque fan or pump. Light-overload use (PlD) stays at 1.1 kW but pulls 3.1 A, a slightly different current shape for lighter cyclic loads. Under UL listing, the normal-use output current is 3 A, heavy-duty 2.1 A, and light-overload 3.0 A — the UL numbers are the ones to use if the installation requires UL compliance.
Communications and I/O
Onboard CAN is the fixed fieldbus interface — no Ethernet port (Industrial Ethernet count is zero), so if the line runs on PROFINET or EtherNet/IP, you'll need an external gateway or a different drive variant. The drive gives you 2 analog inputs and 2 analog outputs, plus 6 digital inputs and 3 digital outputs. That's enough for basic speed reference, run/stop, and a fault relay without an extra I/O module. The CR2032 lithium coin cell (220 mAh, 3 V) keeps the real-time clock and parameter backup alive through a power loss.
Power and thermal budget
Standby loss is 15 W; full-load power consumption is 55 W. The drive is rated for a maximum ambient temperature of 50 °C — no derating required up to that point, but above that you'll need to manage cabinet airflow. Apparent power output is 2.3 kVA. Sound level is 63.1 dB(A), which is audible in a quiet control room but not loud enough to be a nuisance in a machine hall.