The ABB 3AXD50000047768 is an ACS480-04-05A7-4 general purpose drive module for low-voltage AC motors, rated 2.2 kW normal-use output at 5.6 A on a 380–480 V three-phase supply. Frame size R1, IP20 open-type enclosure, and a maximum ambient of 50 °C.
Duty ratings and UL derating
Normal-use output is 2.2 kW / 5.6 A; heavy-duty use drops to 1.5 kW / 4.0 A, and light-overload use holds at 2.2 kW / 5.3 A. Under UL listing the normal-use current is further derated to 4.8 A, heavy-duty to 3.4 A, and light-overload to 4.8 A — so if the machine nameplate calls for UL compliance, size against the UL column, not the IEC one.
Power budget and environment
Draws 91 W at rated load with 15 W standby loss — the standby figure matters for panel heat calc if the drive spends most of its life idle. Sound level is 63.1 dB(A), which is conversational but not silent; plan enclosure vents accordingly. IP20 means it lives inside a clean cabinet, not on the machine frame.
Onboard: 2 analog inputs, 2 analog outputs, 6 digital inputs, 3 digital outputs. Communication is CAN — no onboard Ethernet (0 hardware interfaces for Industrial Ethernet), so if the line uses PROFINET or EtherNet/IP, you will need an optional fieldbus adapter. The control unit is included in the package.