Skip to main content
ABB 3AXD50000047768 — AC Drive (VFD) 480V

ABB 3AXD50000047768 ACS480 Drive Module, 2.2 kW, 5.6 A

MPN3AXD50000047768
Active

ABB ACS480 series, general purpose drive module, 3AXD50000047768, 2.2 kW / 5.6 A, 400 V, IP20, frame size R1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000047768 — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, heavy duty1.5 kW
Output current, heavy duty4.0 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Output current, light overload (UL rating)4.8 A
Apparent power output3.9 kV·A
Efficiency class (IE)IE2
Standby power loss15 W
3AXD50000047768 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000047768 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000047768 — Environmental
ParameterValue
Temperature rating (max.)Maximum 50 °C
3AXD50000047768 — Electrical
ParameterValue
Technical UL/Output Current, Heavy-Duty Use (UL)3.4 A

Product details

The ABB 3AXD50000047768 is an ACS480-04-05A7-4 general purpose drive module for low-voltage AC motors, rated 2.2 kW normal-use output at 5.6 A on a 380–480 V three-phase supply. Frame size R1, IP20 open-type enclosure, and a maximum ambient of 50 °C.

Duty ratings and UL derating

Normal-use output is 2.2 kW / 5.6 A; heavy-duty use drops to 1.5 kW / 4.0 A, and light-overload use holds at 2.2 kW / 5.3 A. Under UL listing the normal-use current is further derated to 4.8 A, heavy-duty to 3.4 A, and light-overload to 4.8 A — so if the machine nameplate calls for UL compliance, size against the UL column, not the IEC one.

Power budget and environment

Draws 91 W at rated load with 15 W standby loss — the standby figure matters for panel heat calc if the drive spends most of its life idle. Sound level is 63.1 dB(A), which is conversational but not silent; plan enclosure vents accordingly. IP20 means it lives inside a clean cabinet, not on the machine frame.

Onboard: 2 analog inputs, 2 analog outputs, 6 digital inputs, 3 digital outputs. Communication is CAN — no onboard Ethernet (0 hardware interfaces for Industrial Ethernet), so if the line uses PROFINET or EtherNet/IP, you will need an optional fieldbus adapter. The control unit is included in the package.

Frequently asked questions

What are the key output ratings for this drive module?

Normal-use output is 2.2 kW at 5.6 A on 380–480 V three-phase. Heavy-duty use is 1.5 kW / 4.0 A. Under UL listing, normal-use current is 4.8 A.

What compliance documentation is available for 3AXD50000047768?

RoHS compliance dated 2023-03-15 per EU Directive 2011/65/EU, REACH compliance dated 2025-09-05, and SCIP number 4b7f0af1-4313-4811-b990-f45b6c1653c8 Finland.

Does this drive include the control unit?

Yes, the control unit is included in the package.

MPN
3AXD50000047768