What this drive module delivers
IP20 enclosure and a maximum ambient of 50 °C — no derating headache in a ventilated cabinet. Standby loss sits at 15 W, which matters for energy-conscious installations or UPS-backed circuits.
I/O and communication at a glance
Two analog inputs and two analog outputs handle speed reference and feedback loops. Six digital inputs and three digital outputs cover start/stop, fault reset, and status indication. CAN onboard for drive-to-drive or controller links — no extra option card needed for basic networking.