Skip to main content
ABB 3AXD50000047791 — AC Drive (VFD) 480V

ABB 3AXD50000047791 ACS480 Drive Module, 5.5 kW, 12.6 A

MPN3AXD50000047791
Active

ABB ACS480 series general purpose drive module, 3AXD50000047791, 5.5 kW / 12.6 A, 380-480 V 3-phase, IP20, frame size R2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000047791 — Power & Output
ParameterValue
Output power, normal duty5.5 kW
Output current, normal duty12.6 A
Output power, heavy duty4.0 kW
Output current, heavy duty9.4 A
Output power, light overload5.5 kW
Output current, light overload12.0 A
Output current, light overload (UL rating)11.0 A
Apparent power output8.7 kV·A
Efficiency class (IE)IE2
Standby power loss16 W
3AXD50000047791 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000047791 — Mechanical & Cooling
ParameterValue
Frame sizeR2
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000047791 — Environmental
ParameterValue
Temperature rating (max.)Maximum 50 °C
3AXD50000047791 — Electrical
ParameterValue
Technical UL/Output Current, Heavy-Duty Use (UL)7.6 A

Product details

The ABB 3AXD50000047791 is an ACS480-04-12A7-4 general purpose drive module for low-voltage AC motors — 5.5 kW normal-use output at 12.6 A on a 400 V three-phase supply, with a heavy-duty rating of 4.0 kW at 9.4 A for tougher loads. Frame size R2, IP20, open type. It includes the control unit, so you're not sourcing a separate controller board for the panel.

Three duty ratings let you match the drive to the load profile. Normal use (IEC) is 5.5 kW / 12.6 A — that's your constant-torque conveyor or pump. Heavy-duty use drops to 4.0 kW / 9.4 A, sized for a higher peak demand cycle. Light-overload use (PlD) stays at 5.5 kW but the current limit is 12.0 A, slightly below the normal-use 12.6 A — useful for variable-torque fans. Under UL listing, the normal-use output current is 11 A, heavy-duty 7.6 A, and light-overload 11.0 A. If your panel carries a UL label, size against those numbers, not the IEC values.

Two analog inputs and two analog outputs are on board — enough for a speed reference and a feedback transducer without an expansion module. Six digital inputs and three digital outputs handle start/stop, fault reset, and a run status relay. The only fieldbus interface is CAN; there is no onboard industrial Ethernet port. If your control network is PROFINET or EtherNet/IP, you'll need an optional fieldbus adapter module.

Frequently asked questions

What is the SCIP number for this drive?

SCIP: 7c31b240-4496-4458-8a39-0107a7e7ffcc Finland, filed for EU waste framework compliance.

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU (date 20230315), REACH registered with substances >0.1% mass declared (date 20250905). UL listing provides derated output currents for North American installations.

Does this drive include a control unit?

Yes, the listing includes the control unit — no separate controller board to order.

MPN
3AXD50000047791