The ABB 3AXD50000047793 is an ACS480-04-026A-4 LV AC general purpose drive module rated for 11 kW normal-use output at 25 A on a 380-480 V three-phase supply. It includes the control unit, so this order code covers the complete drive — not a bare power stage.
Normal-use output is 11 kW at 25 A; heavy-duty use drops to 7.5 kW at 17.0 A. Light-overload use is rated at 11.0 kW and 23.8 A. Under UL listing the normal-use current is 21 A, heavy-duty 14.0 A, light-overload 21.0 A. If your application runs a constant-torque load near the motor nameplate, size against the heavy-duty figure — that 17.0 A (IEC) or 14.0 A (UL) is the continuous rating for a 7.5 kW motor on a conveyor or positive-displacement pump. Apparent power output is 17 kV·A, power consumption at rated load is 390 W, and standby loss sits at 26 W. That standby figure matters if the drive stays powered but idle for long periods — 26 W is low enough to skip a contactor on the line side in most panels.
Two analog inputs and two analog outputs are on board, plus 6 digital inputs and 3 digital outputs. Communication is via CAN; there is no industrial Ethernet interface on this variant. If you need Ethernet/IP, PROFINET, or Modbus TCP, you will need the fieldbus adapter module that plugs into the option slot.
Physical and environmental
R3 frame size, IP20 enclosure, open type per NEMA. Maximum ambient temperature is 50 °C. Frequency range is 47.5 to 63 Hz. Sound level is 65.8 dB(A) — noticeable in a quiet room but unremarkable on a factory floor.
The control board includes a CR2032 lithium coin cell (220 mAh, 3 V) that backs up real-time clock and parameter storage.