ABB 3AXD50000049028 — AC Drive (VFD) 480V

ABB 3AXD50000049028 Drive Control Unit, R10, 250 kW

MPN3AXD50000049028
Active

ABB, Drive Control Unit, 3AXD50000049028, Frame R10, 380-480 V 3-phase, 250 kW / 505 A Normal Use, 200 kW / 361 A Heavy-Duty, IP00, CAN.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000049028 — Power & Output
ParameterValue
Output power, normal duty250 kW
Output current, normal duty505 A
Output power, heavy duty200 kW
Output current, heavy duty361 A
Output power, light overload250 kW
Output current, light overload485 A
Output current, light overload (UL rating)483 A
Apparent power output350 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)400 Hp
Standby power loss423 W
3AXD50000049028 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000049028 — Mechanical & Cooling
ParameterValue
Frame sizeR10
NEMA enclosure typeOpen Type
Degree of protection (IP)IP00
Mounting typeModule
3AXD50000049028 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000049028 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)300 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)361 A

Product details

The ABB 3AXD50000049028 is a drive control unit in frame size R10, rated for 250 kW normal-use output at 505 A and 200 kW heavy-duty at 361 A on a 380-480 V three-phase supply. It ships as a module including the control unit itself, with 2 analog inputs and 2 analog outputs, 6 digital inputs and 3 digital outputs, and CAN communication onboard. The IP00 open-type enclosure and 72 dB(A) sound level place it inside a cabinet — not on the panel door.

Three output current ratings govern the motor load you can hang on this unit. Normal use (In) is 505 A, which maps to 250 kW and 350 kVA apparent power — that is the continuous rating for a standard variable-torque fan or pump load. Light-overload (IlD) sits at 485 A, also 250 kW, for applications with occasional overload peaks. The UL nameplate figures mirror these: 505 A normal-use, 361 A heavy-duty, with horsepower equivalents of 200 Hp and 300 Hp respectively.

Rated for a maximum 40 °C ambient, 5-95% non-condensing humidity, and altitudes up to 1000 m without derating. Standby loss is 423 W; power consumption at rated load is 6492 W. The power factor sits at 0.98. A lithium coin cell (CR2032, 220 mAh, 3 V) backs the real-time clock and parameter memory — expect to replace it during long-term storage or after a few years of powered-off intervals.

Frequently asked questions

What are the key output ratings for this drive control unit?

Normal use: 250 kW / 505 A. Heavy-duty use: 200 kW / 361 A. Light-overload use: 250 kW / 485 A. Apparent power output is 350 kVA.

What communication protocol does this control unit use?

CAN is the listed communication protocol. There are no Industrial Ethernet hardware interfaces onboard.

What is the SCIP number and why does it matter?

The SCIP number is 58f22844-2faf-42d0-845e-c7388e32f3e4 (Finland). It is required for EU waste framework reporting under the SCIP database for articles containing substances of very high concern.