The 3AXD50000049036: Normal-use output is 75 kW / 145 A; light-overload use matches that at 138 A. Heavy-duty use drops to 55 kW / 105 A. The UL ratings track closely: 100 Hp / 124 A for light overload, 75 Hp / 96 A for heavy duty. Pick the duty class that matches your load profile — the drive carries the headroom for pump and fan curves without oversizing.
In the cabinet
Cabinet-built drive — ships as a control unit plus power section. Ambient temperature max 40 °C, humidity 5...95% non-condensing. Power consumption at rated load is 2487 W, apparent power output 100 kV·A. Includes 2 analog inputs, 2 analog outputs, 6 digital inputs, 3 digital outputs. Communication via CAN; no onboard Ethernet. Backup battery: CR2032 lithium coin, 220 mAh.