The 3AXD50000049038: The normal-use output current of 206 A (In) is the rating for continuous duty at 110 kW. For heavy-duty cycles — higher starting torque or overload — the drive is rated 169 A (IhD) at 90 kW. Light-overload use is rated 196 A (IlD) at 110 kW. Under UL listing, heavy-duty output is 125 Hp at 156 A, and light-overload is 150 Hp at 180 A. The apparent power output is 143 kV·A. These numbers define the motor frame size and cable cross-section you need; the drive itself is frame R7. Enclosure is IP21 with NEMA Type 1, suitable for indoor cabinet installation. Ambient temperature is rated to 40 °C maximum, with operating humidity 5-95% non-condensing. The drive includes a control unit and a lithium coin cell (CR2032, 220 mAh) for backup.
The drive provides 2 analog inputs, 2 analog outputs, and 6 digital inputs / 3 digital outputs. Communication is via CAN bus; there are no industrial Ethernet interfaces on this variant. Power consumption at rated load is 3314 W, with a power factor of 0.98.