Drive ratings and duty selection
It delivers 450 kW normal-use output (Pn) at 820 A (In) on a 400 V three-phase supply, with a heavy-duty rating of 355 kW (PhD) at 625 A (IhD). Frame size R11, IP21 enclosure with NEMA Type 1 rating, and a maximum ambient of 40 °C. The drive includes a control unit and draws 13725 W at rated load. Apparent power output is 568 kV·A.
Onboard I/O: 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is via CAN; no onboard Industrial Ethernet port. The drive is cabinet-built, so fieldbus modules are added externally if needed.
Compliance and environmental data
Operating humidity range 5 to 95% RH, frequency 47.5 to 63 Hz. Sound level 72 dB(A). Includes a lithium coin cell CR2032 (220 mAh, 3 V) for backup.