Skip to main content
ABB 3AXD50000121076 — AC Drive (VFD) 480V

ABB 3AXD50000121076 ACS880-31 Drive, 18.5 kW, 38 A

MPN3AXD50000121076
Active

ABB ACS880-31 low harmonic single drive, IEC: Pn 18.5 kW, 38 A, 400 V, frame size R6, IP21, wall-mounted.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000121076 — Power & Output
ParameterValue
Output power, normal duty18.5 kW
Output current, normal duty38 A
Output power, heavy duty15.0 kW
Output current, heavy duty32 A
Output power, light overload18.5 kW
Output current, light overload36 A
Apparent power output26 kV·A
Efficiency class (IE)IE2
Standby power loss49 W
3AXD50000121076 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000121076 — Mechanical & Cooling
ParameterValue
Frame sizeR6
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted
3AXD50000121076 — Environmental
ParameterValue
Temperature rating (max.)Maximum +55 °C

Product details

The 3AXD50000121076: The drive is wall-mounted, frame size R6, with an IP21 degree of protection and NEMA Type 1 enclosure. Ambient temperature limit is +55 °C, altitude up to 4000 m. Communication is via CAN bus. The unit includes 2 analog inputs, 2 analog outputs, and 6 digital inputs with 2 digital outputs.

Three duty ratings are specified: normal use (Pn 18.5 kW, In 38 A), heavy-duty use (PhD 15.0 kW, IhD 32 A), and light-overload use (PlD 18.5 kW, IlD 36 A). Apparent power output is 26 kV·A, with standby loss of 49 W and power consumption at rated load of 851 W. Power factor is unity.

The drive carries an IE2 efficiency level and is exempt from EU ecodesign requirements for low-harmonic drives under Regulation EU/2019/1781 §2.3.d.

Integration notes

Wall-mounted, frame R6. IP21 / NEMA 1 means it is suitable for indoor clean environments without washdown. Ambient up to +55 °C, altitude to 4000 m — no derating needed at typical plant elevations. The unit includes a control unit. Two analog inputs and two analog outputs are available for speed reference or process feedback. Six digital inputs and two digital outputs handle start/stop, fault reset, and status. CAN bus is the onboard fieldbus; no industrial Ethernet interface is fitted. Sound pressure level is 71 dB(A). The battery information notes two CR2032 lithium coin cells (220 mAh, 3 V) for parameter backup.

Frequently asked questions

What are the key output ratings for this drive?

Normal use: 18.5 kW at 38 A. Heavy-duty use: 15.0 kW at 32 A. Light-overload use: 18.5 kW at 36 A.

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508). REACH compliant (date 20250905), with substances above 0.1 mass percentage. SCIP number fcdc24ef-6177-4a20-9ff6-4fd916600fd0 Finland.

What is the enclosure rating and mounting?

IP21, NEMA Type 1, wall-mounted, frame size R6.

What communication protocol does it use?

CAN bus. No industrial Ethernet interface is included.

MPN