The 3AXD50000121076: The drive is wall-mounted, frame size R6, with an IP21 degree of protection and NEMA Type 1 enclosure. Ambient temperature limit is +55 °C, altitude up to 4000 m. Communication is via CAN bus. The unit includes 2 analog inputs, 2 analog outputs, and 6 digital inputs with 2 digital outputs.
Three duty ratings are specified: normal use (Pn 18.5 kW, In 38 A), heavy-duty use (PhD 15.0 kW, IhD 32 A), and light-overload use (PlD 18.5 kW, IlD 36 A). Apparent power output is 26 kV·A, with standby loss of 49 W and power consumption at rated load of 851 W. Power factor is unity.
The drive carries an IE2 efficiency level and is exempt from EU ecodesign requirements for low-harmonic drives under Regulation EU/2019/1781 §2.3.d.
Integration notes
Wall-mounted, frame R6. IP21 / NEMA 1 means it is suitable for indoor clean environments without washdown. Ambient up to +55 °C, altitude to 4000 m — no derating needed at typical plant elevations. The unit includes a control unit. Two analog inputs and two analog outputs are available for speed reference or process feedback. Six digital inputs and two digital outputs handle start/stop, fault reset, and status. CAN bus is the onboard fieldbus; no industrial Ethernet interface is fitted. Sound pressure level is 71 dB(A). The battery information notes two CR2032 lithium coin cells (220 mAh, 3 V) for parameter backup.