Skip to main content
ABB 3AXD50000146024 — AC Drive (VFD) 480V

ABB 3AXD50000146024 ACS880-37 Drive, 250 kW, 442 A

MPN3AXD50000146024
Active

ABB ACS880-37 series, 3AXD50000146024, 250 kW normal-use output, 442 A normal-use current, frame size R11, IP22, NEMA Type 1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000146024 — Power & Output
ParameterValue
Output power, normal duty250 kW
Output current, normal duty442 A
Output power, heavy duty200 kW
Output current, heavy duty363 A
Output power, light overload250 kW
Output current, light overload420 A
Apparent power output306 kV·A
3AXD50000146024 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency48 ... 63 Hz
3AXD50000146024 — Mechanical & Cooling
ParameterValue
Frame sizeR11
NEMA enclosure typeType1
Degree of protection (IP)IP22
3AXD50000146024 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The 3AXD50000146024: Normal-use (Pn 250 kW, In 442 A) is the headline number for continuous motor loads — pumps, fans, conveyors running at nameplate. Heavy-duty (PhD 200 kW, IhD 363 A) is the one you size against for constant-torque loads like extruders or crushers that need full torque at low speed. Light-overload (PlD 250 kW, IlD 420 A) sits between them; the 442 A normal-use figure is the one that fills the BOM line for most applications. The 306 kV·A apparent power output tells you the transformer and cable sizing upstream.

Status is active — no LTB window, no NRND flag. This is a current-production variant, so you can quote it into a BOM without a last-time-buy clock. Sourced to order again.

What fits in the panel

Frame R11 is the physical envelope — expect a cabinet-mounted drive, not a wall-mount puck. IP22 means protected against finger contact and dripping water; keep it indoors or in a NEMA 1 enclosure (which it already carries). Ambient max 40 °C, altitude 1000 m without derating. The 77 dB(A) sound level is noticeable in a quiet control room — plan for separation or ear protection if it runs near operators. Two analog inputs and two analog outputs are on board; 7 digital inputs and 5 digital outputs cover basic I/O without an expansion module. CAN is the onboard fieldbus; no Industrial Ethernet port on this variant, so if the line needs PROFINET or EtherNet/IP, you'll add an option module.

Frequently asked questions

What are the key power ratings for this drive?

Normal-use output is 250 kW at 442 A. Heavy-duty output is 200 kW at 363 A. Light-overload output is 250 kW at 420 A. Apparent power output is 306 kV·A.

What input voltage and frequency does it require?

It requires 380–415 V three-phase input at 48–63 Hz.

What is the enclosure rating and frame size?

Frame size R11, IP22 degree of protection, NEMA Type 1 enclosure.

What compliance documentation is available for this drive?

The SCIP number is 9ECED1FE-316A-4BF4-991E-2606BB5FE13A Finland, covering EU REACH/SCIP requirements. The drive is exempt from EU ecodesign energy efficiency requirements under Regulation EU/2019/1781 §2.3.d as a low-harmonic drive.

MPN
3AXD50000146024