The 3AXD50000146024: Normal-use (Pn 250 kW, In 442 A) is the headline number for continuous motor loads — pumps, fans, conveyors running at nameplate. Heavy-duty (PhD 200 kW, IhD 363 A) is the one you size against for constant-torque loads like extruders or crushers that need full torque at low speed. Light-overload (PlD 250 kW, IlD 420 A) sits between them; the 442 A normal-use figure is the one that fills the BOM line for most applications. The 306 kV·A apparent power output tells you the transformer and cable sizing upstream.
Status is active — no LTB window, no NRND flag. This is a current-production variant, so you can quote it into a BOM without a last-time-buy clock. Sourced to order again.
What fits in the panel
Frame R11 is the physical envelope — expect a cabinet-mounted drive, not a wall-mount puck. IP22 means protected against finger contact and dripping water; keep it indoors or in a NEMA 1 enclosure (which it already carries). Ambient max 40 °C, altitude 1000 m without derating. The 77 dB(A) sound level is noticeable in a quiet control room — plan for separation or ear protection if it runs near operators. Two analog inputs and two analog outputs are on board; 7 digital inputs and 5 digital outputs cover basic I/O without an expansion module. CAN is the onboard fieldbus; no Industrial Ethernet port on this variant, so if the line needs PROFINET or EtherNet/IP, you'll add an option module.