ABB 3AXD50000157983 — AC Drive (VFD) 480V

3AXD50000157983 ABB ACS880-17-0145A-3 Drive, 75 kW, 145 A, F

MPN3AXD50000157983
Active

ABB ACS880-17-0145A-3 regenerative drive, 75 kW / 145 A normal use, 380-415 VAC, 3-phase, Frame R8, IP22, NEMA 1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000157983 — Power & Output
ParameterValue
Output power, normal duty75 kW
Output current, normal duty145 A
Output power, heavy duty55 kW
Output current, heavy duty105 A
Output power, light overload75 kW
Output current, light overload138 A
Output current, light overload (UL rating)- A
Apparent power output100 kV·A
Output power, light overload (UL rating, Hp)- Hp
3AXD50000157983 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency48 ... 63 Hz
3AXD50000157983 — Mechanical & Cooling
ParameterValue
Frame sizeR8
NEMA enclosure typeType1
Degree of protection (IP)IP22
3AXD50000157983 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000157983 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)- Hp
Technical UL/Output Current, Heavy-Duty Use (UL)- A

Product details

Drive identity and key ratings

The ABB ACS880-17-0145A-3 (3AXD50000157983) is a regenerative drive delivering 75 kW normal-use output at 145 A, with heavy-duty capability of 55 kW at 105 A. It runs on a 380 to 415 VAC, 3-phase supply and is housed in a Frame R8 enclosure rated IP22 and NEMA Type 1.

The 75 kW normal-use (Pn) rating matches a standard 100 hp induction motor on a pump or fan. The 145 A normal-use current (In) and 105 A heavy-duty current (IhD) are the numbers to check against your motor nameplate full-load amps. Ambient temperature is limited to 40 °C maximum; above that, derate per the drive's thermal curve. Altitude rating of 1000 m means no derating needed at most sites, but above that you'll need to reduce current per IEC guidelines.

Integration and I/O

The drive includes 2 analog inputs and 2 analog outputs for speed reference or process feedback, plus 7 digital inputs and 5 digital outputs for start/stop, fault reset, and status indication. Communication is via CAN; no onboard Ethernet, so if you need fieldbus, plan for an optional adapter module. The control unit is included. Two lithium coin cells (CR2032) back the real-time clock and parameter storage — expect to replace them every few years during maintenance.

The regenerative design is exempt from EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c), so no energy-efficiency class is declared. The SCIP substance declaration (82D82DAE-9725-4373-865D-AA949B97DE50 Finland) is on file for REACH compliance.

Frequently asked questions

What are the key power ratings of this drive?

Normal-use output is 75 kW at 145 A; heavy-duty output is 55 kW at 105 A; light-overload output is 75 kW at 138 A.

What input voltage and phases does it require?

It requires 380 to 415 VAC, 3-phase, 48 to 63 Hz.

What is the enclosure protection rating?

IP22 with NEMA Type 1 enclosure, suitable for indoor installation where no water spray is present.