Skip to main content
ABB 3AXD50000157990 — AC Drive (VFD) 480V

3AXD50000157990 ABB ACS880-17-0169A-3 Drive R8, 90 kW, 169 A

MPN3AXD50000157990
Active

ABB ACS880-17-0169A-3, frame R8, 90 kW normal-use output, 169 A, 380–415 V 3-phase, IP22, NEMA 1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000157990 — Power & Output
ParameterValue
Output power, normal duty90 kW
Output current, normal duty169 A
Output power, heavy duty75 kW
Output current, heavy duty145 A
Output power, light overload90 kW
Output current, light overload161 A
Output current, light overload (UL rating)- A
Apparent power output117 kV·A
Output power, light overload (UL rating, Hp)- Hp
3AXD50000157990 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency48 ... 63 Hz
3AXD50000157990 — Mechanical & Cooling
ParameterValue
Frame sizeR8
NEMA enclosure typeType1
Degree of protection (IP)IP22
3AXD50000157990 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000157990 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)- Hp
Technical UL/Output Current, Heavy-Duty Use (UL)- A

Product details

The ABB 3AXD50000157990 is an ACS880-17-0169A-3 regenerative drive in frame R8, rated for 90 kW normal-use output at 169 A. Heavy-duty use drops to 75 kW and 145 A. Input is 380–415 V three-phase, 48–63 Hz. Enclosure is IP22 with NEMA Type 1.

Normal-use current is 169 A; light-overload use is 161 A. Heavy-duty current is 145 A. Apparent power output is 117 kV·A. The drive is exempt from EU ecodesign energy-efficiency reporting because it is regenerative. Maximum ambient temperature is 40 °C, altitude 1000 m.

Two analog inputs and two analog outputs are onboard. Digital I/O counts seven inputs and five outputs. Communication is via CAN. No industrial Ethernet interface is fitted.

Frequently asked questions

What are the normal-use and heavy-duty output ratings?

Normal-use output is 90 kW at 169 A; heavy-duty output is 75 kW at 145 A.

What is the input voltage and frequency range?

Input is 380–415 V three-phase, 48–63 Hz.

What enclosure protection does it have?

IP22 with NEMA Type 1.

What is the SCIP number?

SCIP 82D82DAE-9725-4373-865D-AA949B97DE50 Finland.

MPN
3AXD50000157990