ABB 3AXD50000158003 — AC Drive (VFD) 480V

ABB 3AXD50000158003 ACS880-17 Drive, 110 kW, 206 A

MPN3AXD50000158003
Active

ABB ACS880-17 regenerative drive, order code 3AXD50000158003, 110 kW normal-use power, 206 A output current, 380-415 V 3-phase, IP22, R8 frame.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50000158003 — Power & Output
ParameterValue
Output power, normal duty110 kW
Output current, normal duty206 A
Output power, heavy duty90 kW
Output current, heavy duty169 A
Output power, light overload110 kW
Output current, light overload196 A
Output current, light overload (UL rating)- A
Apparent power output143 kV·A
Output power, light overload (UL rating, Hp)- Hp
3AXD50000158003 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency48 ... 63 Hz
3AXD50000158003 — Mechanical & Cooling
ParameterValue
Frame sizeR8
NEMA enclosure typeType1
Degree of protection (IP)IP22
3AXD50000158003 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000158003 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)- Hp
Technical UL/Output Current, Heavy-Duty Use (UL)- A

Product details

The 3AXD50000158003: The 206 A normal-use current (In) is the continuous rating for a standard-duty motor load; the 169 A heavy-duty current (Ihd) governs the same drive under a higher-torque, constant-torque profile. The 143 kVA apparent power rating gives a quick check against transformer sizing. The regenerative topology means the drive returns braking energy to the line, which exempts it from EU ecodesign efficiency requirements under Regulation EU/2019/1781 §2.3.c.

Integration notes

The drive includes the control unit. It communicates via CAN protocol and provides 2 analog inputs, 2 analog outputs, 7 digital inputs, and 5 digital outputs. The enclosure is IP22 with NEMA Type1 rating, suitable for indoor installation. Ambient temperature is limited to 40 °C, altitude to 1000 m, and humidity 5-95% non-condensing. Sound level is 70 dB(A). Two lithium coin cells (CR2032) back up the real-time clock and parameter storage.

Frequently asked questions

What are the key ratings of this drive?

Normal-use output power is 110 kW with 206 A current; heavy-duty output is 90 kW at 169 A; input voltage is 380-415 V three-phase, 48-63 Hz. Apparent power rating is 143 kVA.

What is the SCIP number for this drive?

The SCIP number is 82D82DAE-9725-4373-865D-AA949B97DE50 Finland.

What enclosure protection does it have?

IP22 with NEMA Type1 rating.

MPN