The 3AXD50000199099: Normal-use output is 22 kW at 50 A; heavy-duty use also 22 kW but at 45 A, and light-overload use 22 kW at 48 A. Under UL listing the normal-use current derates to 42 A, heavy-duty to 40 A, and light-overload to 42 A — so if the installation requires UL compliance, size the motor load against those lower figures. Apparent power output is 35 kV·A. Standby loss is 38 W; full-load power consumption is 672 W. Efficiency class is IE2.
I/O and interfaces
Built-in I/O includes 2 analog inputs, 2 analog outputs, 6 digital inputs and 3 digital outputs. Communication is via CAN protocol; there is no onboard industrial Ethernet interface. A CR2032 lithium coin cell (220 mAh, 3 V) backs the real-time clock.
Sourcing
The spec table and datasheet carry the full electrical and mechanical data; the key procurement check is confirming the UL current derating if the panel requires a UL-listed nameplate.