Output ratings and duty cycles
The 3AXD50000199587: Normal-use output current is 293 A (160 kW), heavy-duty use is 246 A (132 kW), and light-overload use is 278 A (160 kW). Apparent power output is 203 kV·A. The module carries an IE2 efficiency level; regenerative drives are exempt from EU ecodesign requirements per Regulation EU/2019/1781, §2.3.c.
Rated for a maximum ambient temperature of +55 °C, altitude up to 4000 m, and non-condensing humidity of 5–95%. Enclosure is IP20, NEMA Open Type, in an R11 frame size. Standby loss is 202 W; sound level is 75 dB(A). The module is supplied with a control unit included.
Provides 2 analog inputs, 2 analog outputs, 6 digital inputs, and 2 digital outputs. Communication is via CAN; no industrial Ethernet interface is fitted. A CR2032 lithium coin cell (2 pcs, 220 mAh, 3 V) backs the real-time clock.