3AXD50000275717 — Power & Output
ParameterValue
Output power, normal duty11 kW
Output current, normal duty25 A
Output power, heavy duty7.5 kW
Output current, heavy duty17.0 A
Output power, light overload11.0 kW
Output current, light overload23.8 A
Output current, light overload (UL rating)21.0 A
Apparent power output17 kV·A
Efficiency class (IE)IE2
Standby power loss26 W
3AXD50000275717 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000275717 — Mechanical & Cooling
ParameterValue
Frame sizeR3
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000275717 — Environmental
ParameterValue
Temperature rating (max.)Maximum 50 °C
3AXD50000275717 — Electrical
ParameterValue
Technical UL/Output Current, Heavy-Duty Use (UL)14.0 A

Product details

The ABB 3AXD50000275717 is an ACH480-series HVAC drive module rated for 11 kW normal-use output (25 A) on a 380–480 V three-phase supply, with heavy-duty capability at 7.5 kW (17.0 A). Frame size R3, IP20 open-type enclosure. Includes the control unit — no separate controller to order. BACnet on board for building management integration.

The kit includes the control unit, so the drive arrives as a single assembly. No holes in the box — the control unit is integrated, not a separate line item. The lithium coin cell (CR2032, 220 mAh) is fitted for real-time clock backup.

Normal-use output current is 25 A (21 A under UL listing); heavy-duty drops to 17.0 A (14.0 A UL). Light-overload use sits at 23.8 A (21.0 A UL). The 17 kV·A apparent power output matches the 11 kW motor load for typical HVAC fan and pump curves. Standby loss is 26 W — relevant for continuous building-services operation.

Frequently asked questions

What is the SCIP number for this drive?

SCIP d47e4459-83a3-4590-a72e-d9674f7109ad Finland is listed for this module.

What compliance documentation does ABB provide for this drive?

RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863, and REACH declaration (contains substances > 0.1% mass). UL listing with derated output currents is also on file.

MPN
3AXD50000275717