ABB 3AXD50000447831 — AC Drive (VFD) 480V

ABB 3AXD50000447831 ACS880-04 Drive Module, 710 kW / 1250 A

MPN3AXD50000447831
Active

ABB ACS880-04 drive module, 3-phase 380-415 V, 710 kW / 1250 A normal-use output, IP00 open type, module for cabinet building.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000447831 — Power & Output
ParameterValue
Output power, normal duty710 kW
Output current, normal duty1250 A
Output power, heavy duty500 kW
Output current, heavy duty935 A
Output power, light overload630 kW
Output current, light overload1200 A
3AXD50000447831 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency50/60 Hz
3AXD50000447831 — Mechanical & Cooling
ParameterValue
NEMA enclosure typeOpen Type
Degree of protection (IP)IP00
Mounting typeModule for cabinet building

Product details

The ABB 3AXD50000447831 is a drive module rated for 710 kW normal-use output at 1250 A on a 380-415 V three-phase supply. It also carries heavy-duty and light-overload ratings: 500 kW / 935 A for heavy-duty cycles and 630 kW / 1200 A for light-overload applications.

The normal-use rating (710 kW / 1250 A) is the continuous output for typical industrial loads — conveyors, pumps, fans running at constant speed. The heavy-duty rating (500 kW / 935 A) applies when the drive must handle higher peak torque or frequent starts, such as on a crusher or extruder. The light-overload rating (630 kW / 1200 A) sits between the two, suited for applications with moderate overload demands. Matching the duty class to the driven load avoids oversizing or nuisance trips.

This module is designed for cabinet building — it mounts inside a panel, not as a standalone unit. The IP00 rating means no protection against dust ingress or accidental contact; the cabinet must provide the IP rating required by the installation environment. The open-type NEMA classification confirms the same: intended for indoor, pollution-controlled enclosures only.

Frequently asked questions

What are the key output ratings for this drive module?

Normal-use output is 710 kW / 1250 A; heavy-duty is 500 kW / 935 A; light-overload is 630 kW / 1200 A. Input is 380-415 V three-phase at 50/60 Hz.

What enclosure type does this module have?

It is IP00 open type (NEMA Open Type), meaning it must be installed inside a cabinet that provides the required environmental protection.

How do I source this part?

This is an active ABB ACS880-04 module. Submit an RFQ for a firm delivery commitment — no stock or lead-time numbers are published here, but we quote to order against your BOM line.

MPN