Skip to main content
ABB 3AXD50000662494 — AC Drive (VFD) 480V

ABB 3AXD50000662494 ACS180 Drive Module, 4 kW, 9.4 A

MPN3AXD50000662494
Active

ABB ACS180 LV AC machinery drive module, 3AXD50000662494, Frame R1, 4 kW / 9.4 A normal duty, 380-480 V 3-phase.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3AXD50000662494 — Power & Output
ParameterValue
Output power, normal duty4 kW
Output current, normal duty9.4 A
Output power, heavy duty3 kW
Output current, heavy duty7.2 A
Output power, light overload4 kW
Output current, light overload8.9 A
Apparent power output6.5 kV·A
Efficiency class (IE)IE2
Standby power loss9 W

Input / Supply

3AXD50000662494 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3AXD50000662494 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Environmental

3AXD50000662494 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50000662494 is an ACS180-series LV AC machinery drive module rated for 4 kW normal-duty output at 9.4 A, with heavy-duty capability of 3 kW at 7.2 A. It accepts 380-480 V three-phase input across 47.5-63 Hz and carries an IE2 efficiency classification. The R1 frame keeps the panel footprint compact, and the IP20 enclosure suits clean indoor environments.

Duty ratings and thermal margin

The normal-duty (Pn) rating of 4 kW at 9.4 A is the headline number, but the heavy-duty (PhD) curve of 3 kW at 7.2 A is what governs constant-torque applications like conveyors or positive-displacement pumps. Light-overload (PlD) at 4 kW / 8.9 A sits between the two. The 9 W standby loss is low enough that forced cooling in a small cabinet is optional at 40 °C ambient.

Frame R1 mounts directly to a backplate or DIN rail. The Open Type enclosure rating means it requires installation inside a suitable cabinet. No external dimension exceeds 50 cm, which simplifies panel layout. Verify the bus voltage range matches your transformer taps before commissioning.

Frequently asked questions

What is the frame size of this drive?

The frame size is R1, which is the smallest frame in the ACS180 series, suitable for panel-mounting in space-constrained layouts.

What duty ratings does this drive support?

Normal-duty output is 4 kW at 9.4 A, heavy-duty is 3 kW at 7.2 A, and light-overload is 4 kW at 8.9 A. The heavy-duty rating governs constant-torque loads.

What compliance documentation is available?

The SCIP number 5d07f008-496e-4abd-8f50-616cb485c791 Finland is registered for EU substance compliance. The WEEE category is 5 (Small Equipment). Standard ABB declarations for RoHS, REACH, and CE are available upon request.

MPN
3AXD50000662494