Skip to main content
ABB 3AXD50000707263 — AC Drive (VFD) 480V

ABB 3AXD50000707263 ACQ80 Solar Pump Drive, 2.2 kW, 5.6 A

MPN3AXD50000707263
Active

ABB ACQ80-04-02kW2-4 LV AC drive module for solar pumps, 2.2 kW / 5.6 A normal duty, 380-480 V, IP20, CAN, Frame R0.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50000707263 — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, heavy duty1.5 kW
Output current, heavy duty4 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Apparent power output4.0 kV·A
Efficiency class (IE)IE2
Standby power loss15 W
3AXD50000707263 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000707263 — Mechanical & Cooling
ParameterValue
Frame sizeR0
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000707263 — Environmental
ParameterValue
Temperature rating (max.)Maximum 50 °C

Product details

The ABB 3AXD50000707263 is an ACQ80-04-02kW2-4 low-voltage AC drive module purpose-built for solar pump applications. It delivers 2.2 kW output power at 5.6 A in normal (light-overload) use, and 1.5 kW at 4 A in heavy-duty use — the rating that governs continuous motor operation in hot, high-irradiance conditions. Input accepts 380-480 V three-phase, 47.5-63 Hz, so it handles both 50 Hz and 60 Hz grids without derating. The drive includes a control unit, mounts as a module (Frame R0), and is rated IP20 for clean indoor panel environments.

Normal-use output (2.2 kW / 5.6 A) matches the pump motor's nameplate for most solar tracking and booster applications. Heavy-duty output (1.5 kW / 4 A) is the rating to size against when ambient temperature hits 50 °C or the pump sees sustained overload — the drive's maximum ambient is 50 °C, so in a hot cabinet that heavy-duty number is the one that keeps the drive online. Standby loss is 15 W, power consumption at full load is 91 W — low enough that cabinet ventilation requirements are modest for a 2.2 kW class drive.

The drive provides 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs — enough for pressure transducer feedback, start/stop from a PLC or float switch, and a run-status relay. Communication is CAN-based, not Ethernet; if the site uses Modbus TCP or PROFINET, a separate gateway or option module is needed. The lithium coin cell (CR2032, 220 mAh) keeps real-time clock and parameter backup alive during power loss.

Frequently asked questions

What compliance documentation does this drive have?

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (declaration date 20240603). REACH compliant with substances > 0.1% (declaration date 20250905). SCIP number 97657ee2-2ad1-409a-811f-7a3734b200a6 Finland.

What is the heavy-duty output rating and why does it matter?

Heavy-duty output is 1.5 kW at 4 A. This is the rating to use when sizing the drive for continuous operation at 50 °C ambient or for pump loads with sustained overload — it ensures the drive stays within its thermal limits.

What communication protocol does this drive use?

CAN. There is no onboard Industrial Ethernet interface (0 hardware interfaces for Industrial Ethernet), so integration into Modbus TCP or PROFINET networks requires an external gateway or option module.

MPN
3AXD50000707263