Specifications

3AXD50000707454 — Power & Output
ParameterValue
Output power, normal duty22 kW
Output current, normal duty50 A
Output power, heavy duty22 kW
Output current, heavy duty45 A
Output power, light overload22 kW
Output current, light overload48 A
Apparent power output35 kV·A
Efficiency class (IE)IE2
Standby power loss38 W
3AXD50000707454 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000707454 — Mechanical & Cooling
ParameterValue
Frame sizeR3
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000707454 — Environmental
ParameterValue
Temperature rating (max.)Maximum 50 °C

Product details

The ABB 3AXD50000707454 is an ACQ80-04-022kW-4 LV AC drive module purpose-built for solar pump applications. It delivers 22 kW normal-use output at 50 A, with heavy-duty and light-overload ratings also at 22 kW (45 A and 48 A respectively). Input is 380-480 V three-phase, 47.5-63 Hz. Frame size R3, IP20 open-type enclosure.

The 22 kW power rating holds across all three duty classes (normal, heavy, light-overload), which is unusual — most drives derate for heavy-duty. Here the current drops from 50 A to 45 A, but power stays flat, so the drive is thermally sized for sustained pump loads. The 35 kV·A apparent power rating confirms it can handle the inrush of a 22 kW motor on start. Standby loss is 38 W — relevant for solar installations where every watt of idle draw cuts into pump runtime. Efficiency class IE2 is baseline for this power band; don't expect premium efficiency, but it's adequate for a pump duty cycle.

Built-in I/O: 2 analog inputs, 2 analog outputs, 6 digital inputs, 3 digital outputs. No onboard Ethernet — the only hardware interface is CAN. For solar pump control that's often sufficient (CAN to a pump controller or SCADA gateway), but if you need Modbus TCP or PROFINET, you'll add an external gateway.

Frequently asked questions

What compliance documentation is available?

RoHS compliant (EU Directive 2011/65/EU, amendment 2015/863) and REACH registered (contains substances > 0.1% mass). SCIP number 2833fe5f-6cc6-4962-a94c-7cc7cd36b801 Finland is on file.

What are the key output ratings?

Normal use: 22 kW, 50 A. Heavy-duty: 22 kW, 45 A. Light-overload: 22 kW, 48 A. Apparent power: 35 kV·A.

What is the input voltage and frequency range?

380-480 V three-phase, 47.5-63 Hz.

MPN
3AXD50000707454