ABB 3AXD50000716623 — AC Drive (VFD) 480V

ABB 3AXD50000716623 Drive Control Unit, 0.55 kW, MODBUS, IP2

MPN3AXD50000716623
Active

ABB drive control unit, 3AXD50000716623, R0 frame, 0.55 kW / 1.8 A normal use, 380-480 V 3-phase, MODBUS, IP20, Open Type.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3AXD50000716623 — Power & Output
ParameterValue
Output power, normal duty0.55 kW
Output current, normal duty1.8 A
Output power, heavy duty0.37 kW
Output current, heavy duty1.2 A
Output power, light overload0.55 kW
Output current, light overload1.7 A
Output current, light overload (UL rating)1.6 A
Apparent power output1.2 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)0.75 Hp
Standby power loss7 W

Input / Supply

3AXD50000716623 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47 ... 63 Hz

Mechanical & Cooling

3AXD50000716623 — Mechanical & Cooling
ParameterValue
Frame sizeR0
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Environmental

3AXD50000716623 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Electrical

3AXD50000716623 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)0.5 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)1.1 A

Product details

This ABB control unit (order code 3AXD50000716623) is the brains for a small drive — R0 frame, rated 0.55 kW normal use at 1.8 A output, with a heavy-duty rating of 0.37 kW / 1.2 A for tougher cyclic loads. It runs on 380-480 V three-phase, 47-63 Hz, and talks MODBUS over its built-in serial port. The unit includes the control electronics and the power stage — no separate power supply needed. Standby loss is just 7 W, so it won't heat up a small cabinet. Power factor sits at 0.98, which keeps the line side clean. It carries 2 analog inputs, 1 analog output, and 4 digital inputs / 2 digital outputs — enough for a basic VFD application like a fan, pump, or conveyor. Efficiency is IE2, which is standard for this power class.

Integration notes

The MODBUS interface uses the standard RTU protocol; no industrial Ethernet on this unit (0 hardware interfaces for Ethernet). Wire the 380-480 V three-phase input through a line filter if the installation requires EMC compliance. The analog I/O gives you one speed reference input and one output for speed or current feedback.

Frequently asked questions

What compliance documentation does this drive carry?

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 (date 2025-01-06). REACH compliant with substances > 0.1% mass (date 2025-09-05). UL listings cover output ratings: 0.75 Hp / 1.6 A normal use, 0.5 Hp / 1.1 A heavy-duty use, and 0.75 Hp light-overload use.

What is the SCIP number for this part?

The SCIP number is bc3f21f6-ab11-453c-8372-42a57e38dab9 Finland.

What is the altitude rating?

Rated for altitudes up to 2000 m without derating.

MPN