ABB 3AXD50000747511 — AC Drive (VFD) 480V

ABB 3AXD50000747511 ACS530-01-03A4-4, 1.1 kW, 3.3 A

MPN3AXD50000747511
Active

ABB ACS530-01-03A4-4, 1.1 kW, 3.3 A, 380-480 V 3-phase, IP20, frame R1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000747511 — Power & Output
ParameterValue
Output power, normal duty1.1 kW
Output current, normal duty3.3 A
Output power, light overload1.1 kW
Output current, light overload3.1 A
Apparent power output2.3 kV·A
Efficiency class (IE)IE2
Standby power loss14 W
3AXD50000747511 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000747511 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000747511 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50000747511 is an ACS530-01-03A4-4 drive rated for 1.1 kW normal-use output at 3.3 A, fed from a 380 to 480 V three-phase supply. Standby loss sits at 14 W, a figure worth noting when sizing the cabinet cooling or calculating total heat load on a sealed enclosure.

The 1.1 kW normal-use rating (Pn) and 3.3 A output current (In) define the continuous motor capacity on a standard 400 V supply. Light-overload duty (PlD) is also 1.1 kW at 3.1 A, so the drive is sized for constant-torque loads like conveyors or pumps without headroom for short-term overload — if your application demands a 150 % overload for 60 seconds, step up to the next frame. The 2.3 kVA apparent power output confirms the drive's transformer capacity for sizing the upstream line reactor or input fusing. IP20 protection means it is suited for clean, dry indoor panel mounting; no wash-down capability, so keep it out of splash zones.

Installation notes

Mounts as an open-type module (NEMA Open Type) inside a cabinet. The 47.5 to 63 Hz input frequency range covers both 50 Hz and 60 Hz grids without derating. Maximum ambient temperature is 40 °C; above that, derate the output current per the thermal curve in the manual. Efficiency class IE2 is standard for this power band — not premium efficiency, but adequate for most constant-speed applications where the drive is paired with an IE2 motor.

Frequently asked questions

What is the standby loss of this drive?

Standby loss is 14 W, a figure to include in enclosure heat-load calculations.

MPN
3AXD50000747511