The 3AXD50000747535: Output current of 5.6 A normal use (In) and 5.3 A light-overload (IlD) means the drive can sustain 5.6 A continuously and 5.3 A under light overload conditions. Standby loss of 14 W is the idle power draw — relevant for panel heat calculations in a sealed cabinet. Input voltage range 380-480 V, 3-phase, 47.5-63 Hz. Efficiency class IE2.

ABB 3AXD50000747535 ACS530-01 Drive, 2.2 kW, Frame R1
MPN3AXD50000747535
Active
ABB ACS530-01, 2.2 kW VFD, frame size R1, 3-phase 380-480 V, IP20, active production.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Output power, normal duty | 2.2 kW |
| Output current, normal duty | 5.6 A |
| Output power, light overload | 2.2 kW |
| Output current, light overload | 5.3 A |
| Apparent power output | 3.9 kV·A |
| Efficiency class (IE) | IE2 |
| Standby power loss | 14 W |
| Parameter | Value |
|---|---|
| Input voltage range | 380 ... 480 V |
| Number of phases | 3-phase |
| Frequency | 47.5 ... 63 Hz |
| Parameter | Value |
|---|---|
| Frame size | R1 |
| NEMA enclosure type | Open Type |
| Degree of protection (IP) | IP20 |
| Mounting type | Module |
| Parameter | Value |
|---|---|
| Temperature rating (max.) | Maximum 40 °C |
Product details
Frequently asked questions
What is the frame size of this drive?
Frame size R1 — the smallest frame in the ACS530 family. Panel cutout and mounting dimensions follow ABB's R1 standard.
What is the standby power loss?
14 W standby loss. This is the power the drive consumes when idle (no motor running). Useful for panel thermal calculations.
What is the normal-use output power and current?
2.2 kW normal-use power (Pn), 5.6 A normal-use output current (In). Light-overload ratings are 2.2 kW (PlD) and 5.3 A (IlD).
MPN
3AXD50000747535