Skip to main content
ABB 3AXD50000750214 — AC Drive (VFD) 480V

ABB 3AXD50000750214 ACQ531-01-09A5-4 Drive, 4 kW, 9.4 A, Fra

MPN3AXD50000750214
Active

ABB ACQ531 series drive, order code 3AXD50000750214, 4 kW output, 9.4 A rated current, Frame R1, 380-480 V 3-phase input, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000750214 — Power & Output
ParameterValue
Output power, normal duty4 kW
Output current, normal duty9.4 A
Output power, light overload4 kW
Output current, light overload8.9 A
Apparent power output6.5 kV·A
Efficiency class (IE)IE2
Standby power loss14 W
3AXD50000750214 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000750214 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000750214 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50000750214 is an ACQ531-01-09A5-4 drive built for a 4 kW motor on a 380-480 V three-phase supply, delivering 9.4 A continuous output under normal duty. Frame R1 keeps the footprint compact — fits standard panel layouts without requiring oversized backplate cutouts. Standby loss holds at 14 W, so the heat load inside the enclosure stays manageable even in a densely packed cabinet.

The 9.4 A normal-use current (In) is the number to match against your motor's full-load amps. Light-overload duty drops to 8.9 A.

Mounting and environment notes

Frame R1 drives are typically DIN-rail or panel-mount. Ambient temperature maxes at 40 °C; above that, derate the output current or add forced ventilation. The open-type NEMA rating (no gasket seal) reinforces that this goes in a clean, dry enclosure. WEEE category 5 applies — small equipment under 50 cm in any dimension.

Frequently asked questions

What is the frame size of this drive?

Frame R1, which keeps the footprint compact for standard panel layouts.

What is the standby power loss?

14 W, a low figure that helps manage enclosure heat load.

What input voltage and phases does it accept?

380-480 V three-phase, 47.5-63 Hz.

What is the output power and current rating?

4 kW normal-use output with 9.4 A continuous current; light-overload rating is 8.9 A.