Skip to main content
ABB 3AXD50000750245 — AC Drive (VFD) 480V

ABB 3AXD50000750245 ACQ531-01-026A-4 PN, 11 kW, 25 A

MPN3AXD50000750245
Active

ABB ACQ531-01-026A-4 PN, 11 kW, 25 A, Frame Size R2, 380-480 V 3-phase, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000750245 — Power & Output
ParameterValue
Output power, normal duty11 kW
Output current, normal duty25 A
Output power, light overload11 kW
Output current, light overload23.8 A
Apparent power output17.0 kV·A
Efficiency class (IE)IE2
Standby power loss15 W
3AXD50000750245 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000750245 — Mechanical & Cooling
ParameterValue
Frame sizeR2
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000750245 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50000750245 is an ACQ531-01-026A-4 PN drive rated for 11 kW normal-use output at 25 A, in Frame Size R2. It accepts 380-480 V three-phase input and carries IP20 protection for panel-mount installations.

The 11 kW normal-use power rating (Pn) and 25 A output current (In) define the continuous motor capacity this drive handles without overload cycling. The light-overload rating sits at 11 kW and 23.8 A — essentially the same headroom, so this unit is specced for constant-torque applications rather than high-overload duty cycles. Standby loss of 15 W is the heat the drive dissipates when powered but not driving a motor. Frame Size R2 determines the physical footprint and mounting hole pattern. If you're replacing an existing R2-frame ABB drive, the mechanical swap is direct. For a new panel layout, the R2 envelope is the dimension to design around.

Sourcing this order code against an RFQ confirms the exact firmware and hardware revision for the application.

Installation constraints

Maximum ambient temperature is 40 °C, so derate or forced ventilation is needed if the panel ambient exceeds that. Three-phase input only.

Frequently asked questions

What is the frame size of this drive?

The drive is Frame Size R2, which determines its physical mounting footprint and panel cutout dimensions.

What is the standby power loss?

Standby loss is 15 W. This is the heat dissipated when the drive is powered but not running a motor, relevant for enclosure thermal calculations.

What input voltage and phases does it require?

It requires 380-480 V three-phase input, with a frequency range of 47.5 to 63 Hz.

MPN
3AXD50000750245