The 3AXD50000814077: The normal-use output (Pn) is 5.5 kW at 12.6 A — that's the rating for typical constant-torque applications like conveyors or pumps. For heavy-duty cycles, say a crusher or a press with repeated peak torque, the drive is rated 4 kW at 9.4 A. Light-overload use, where the load profile is less demanding, still lands at 5.5 kW but with a slightly lower current limit of 12.0 A. The UL column confirms the same derating: 5 Hp heavy-duty at 7.6 A, 7.5 Hp light-overload at 11.0 A. So if you're sizing for a 5.5 kW motor on a standard pump, the normal-use figure applies; if the machine cycles hard, drop to the heavy-duty line.
I/O and communication — what's on board
The module carries 4 digital inputs and 2 digital outputs, plus 2 analog inputs and 1 analog output. That's enough for basic speed reference and a couple of feedback signals without an extra I/O module. MODBUS is the onboard protocol; no Industrial Ethernet interface is fitted (0 hardware interfaces listed), so if you need PROFINET or EtherNet/IP, you'll be adding an option card or a gateway. The control unit is included, so the drive is ready to accept commands once wired.
Environmental limits and installation notes
Maximum ambient temperature is 40 °C, with a relative humidity range of 5 to 95% non-condensing. The drive is rated for installation up to 2000 m altitude — beyond that, derating applies. Enclosure is IP20 (Open Type per NEMA), so it's intended for a clean, dry cabinet, not for washdown areas. Sound level is 62 dB(A), standby loss is 12 W, and total power consumption at rated output is 157 W. Efficiency is IE2 class, which is standard for this generation of drives.
RoHS compliance follows EU Directive 2011/65/EU with the 2015/863 amendment, dated 2025-01-06. REACH declaration confirms the substance threshold is met, dated 2025-09-05. The SCIP number is c4c7e908-d15d-4601-993d-bf271f952213 (Finland). WEEE category is 5 (small equipment under 50 cm). No battery is included. These are the documents you'll want for your compliance file — they're current and dated.
Sourcing this drive
Because the lifecycle stage is current, this is a standard production part — no LTB window to watch, no broker hunt needed. If you're freezing a BOM or filling a line-down slot, the normal-use rating (5.5 kW, 12.6 A, 380-480 V) is the one to spec against. The R2 frame size is compact enough for a standard panel layout.