Skip to main content
ABB 3AXD50000814176 — AC Drive (VFD) 480V

ABB 3AXD50000814176 ACS580 drive module, 7.5 kW, 17.0 A, IP2

MPN3AXD50000814176
Active

ABB ACS580 drive module, Frame R2, 380-480 V 3-phase, 7.5 kW / 17.0 A normal use, 5.5 kW / 12.6 A heavy-duty, IP20, MODBUS, IE2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3AXD50000814176 — Power & Output
ParameterValue
Output power, normal duty7.5 kW
Output current, normal duty17.0 A
Output power, heavy duty5.5 kW
Output current, heavy duty12.6 A
Output power, light overload7.5 kW
Output current, light overload16.2 A
Output current, light overload (UL rating)14.0 A
Apparent power output12 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)10 Hp
Standby power loss12 W

Input / Supply

3AXD50000814176 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47 ... 63 Hz

Mechanical & Cooling

3AXD50000814176 — Mechanical & Cooling
ParameterValue
Frame sizeR2
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Environmental

3AXD50000814176 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Electrical

3AXD50000814176 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)7.5 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)11.0 A

Product details

The ABB 3AXD50000814176 is a drive module in Frame R2, sized for a 7.5 kW motor at 17.0 A under normal-use (light-overload) duty on a 380-480 V three-phase supply. Heavy-duty use drops the rating to 5.5 kW / 12.6 A. The IP20 enclosure means it is intended for panel mounting. Built-in MODBUS RTU on the control board handles the fieldbus link; there is no industrial Ethernet port, so if the line uses PROFINET or EtherNet/IP, an optional fieldbus adapter will be needed. The 2 analog inputs and 1 analog output cover basic speed reference and feedback, while the 4 digital inputs and 2 digital outputs manage start/stop, fault reset, and run status. Power consumption at rated load is 224 W, with a standby loss of 12 W — relevant for panel thermal calculations. Sound level is 62 dB(A), typical for a drive of this frame size. The module includes the control unit; no separate controller board to order.

The drive carries three duty ratings. Normal use (light-overload): 7.5 kW / 17.0 A. Heavy-duty use: 5.5 kW / 12.6 A. Light-overload use is listed at 7.5 kW / 16.2 A. The UL ratings follow the same pattern: heavy-duty at 7.5 Hp / 11.0 A, light-overload at 10 Hp / 14.0 A. The IE2 efficiency level means the drive meets the standard for variable-speed drives in the EU; it is not the highest tier (IE3 or IE4), but for many industrial applications IE2 is the baseline. Power factor is 0.98, which keeps line-side reactive current low.

Mounting type is module — it bolts into a panel or onto a backplate. Frame R2 is a compact size. Ambient temperature is rated to a maximum of 40 °C, with operating humidity from 5 to 95 % non-condensing. Altitude is rated to 2000 m without derating. The NEMA enclosure type is Open Type, consistent with the IP20 degree of protection. No battery or cell is included, so no periodic battery replacement. WEEE category is 5 (Small Equipment, external dimension under 50 cm).

Frequently asked questions

What compliance documentation is available for this drive?

RoHS compliance follows EU Directive 2011/65/EU and Amendment 2015/863 (declaration date 2025-01-06). REACH information confirms substances above 0.1 mass percentage (declaration date 2025-09-05). The SCIP number is c4c7e908-d15d-4601-993d-bf271f952213 Finland. UL ratings are provided for heavy-duty and light-overload use.

What are the key electrical ratings for this drive?

Input voltage 380-480 V three-phase, 47-63 Hz. Normal-use output 7.5 kW / 17.0 A, heavy-duty 5.5 kW / 12.6 A, light-overload 7.5 kW / 16.2 A. Apparent power output is 12 kV·A. Power consumption at rated load is 224 W, standby loss 12 W.

What communication protocol does this drive support?

Built-in MODBUS RTU. No industrial Ethernet port is included on the control board; an optional fieldbus adapter is required for protocols like PROFINET or EtherNet/IP.

What is the environmental rating for this drive?

IP20 / NEMA Open Type. Maximum ambient temperature 40 °C, operating humidity 5-95 % non-condensing, altitude 2000 m without derating. Sound level 62 dB(A).

MPN
3AXD50000814176