Skip to main content
ABB 3AXD50000865048 — AC Drive (VFD) 480V

ABB 3AXD50000865048 ACQ580-01 Drive, 169 A, 60 Hp

MPN3AXD50000865048
Active

ABB ACQ580-01, LV AC irrigation wall-mounted single drive, UL: Pld 60 Hp, 169 A, 460 V, frame R7, NEMA Type 1, IP21, 3-phase, 208-240 V, 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000865048 — Input / Supply
ParameterValue
Input voltage range208 ... 240 V
Number of phases3-phase
Frequency50/60 Hz
3AXD50000865048 — Power & Output
ParameterValue
Output current, light overload (UL rating)169 A
Output power, light overload (UL rating, Hp)60 Hp
3AXD50000865048 — Mechanical & Cooling
ParameterValue
Frame sizeR7
NEMA enclosure typeType1
Degree of protection (IP)IP21
3AXD50000865048 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)50 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)143 A

Product details

The 3AXD50000865048: The 143 A heavy-duty figure is the continuous current at rated switching frequency for constant-torque loads — think submersible or turbine pumps that see full torque across the speed range. The 169 A light-overload rating gives headroom for variable-torque centrifugal pumps where peak demand is brief. If your BOM calls for a drive that can sustain 143 A in a 50 Hp motor application, this matches. If the pump curve is strictly centrifugal, the 60 Hp / 169 A rating is the continuous limit before derating.

NEMA Type 1 with IP21 means it is drip-proof and intended for indoor mounting — no outdoor weather exposure. The R7 frame is a wall-mount package; confirm gland-plate clearance for incoming power and motor cables. The drive is 3-phase only; single-phase supply will not work.

Listed as active product status. For a BOM freeze or line-down replacement, the active lifecycle means standard lead times apply through the ABB channel.

Frequently asked questions

What are the key ratings for this drive?

Heavy-duty UL output is 50 Hp / 143 A; light-overload UL output is 60 Hp / 169 A. Input voltage is 208-240 V three-phase, 50/60 Hz.

What enclosure type does this drive have?

NEMA Type 1 with an IP21 degree of protection.

What frame size is the 3AXD50000865048?

Frame size R7.

MPN